Product Details | FIXED ATTENUATOR

5985-01-596-9565 A device for reducing the strength of an alternating current signal by a fixed or predetermined amount, without causing appreciable signal distortion, by maintaining correct impedance match.

Part Alternates: 23AH5, 5985-01-596-9565, 01-596-9565, 5985015969565, 015969565

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 25 MAY 2011 01-596-9565

Cross Reference | NSN 5985-01-596-9565

Part Number Cage Code Manufacturer
23AH5 64671 AEROFLEX / INMET, INC. DBA INMET

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-01-596-9565

Technical Data | NSN 5985-01-596-9565

Characteristic Specifications
INPUT IMPEDANCE RATING IN OHMS 50.0
FREQUENCY RANGE 0.0 GIGAHERTZ MINIMUM AND
VOLTAGE STANDING WAVE RATIO 1.15 AND
VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE 0.0 TO 4.0 GIGAHERTZ AND
RF SIGNAL ATTENUATION IN DECIBELS 5.0
POWER RATING 250.0 WATTS PEAK
OPERATING TEMP RANGE -65.0 TO 125.0 DEG CELSIUS
BODY STYLE ROUND, TERMINAL/TERMINALS IN OPPOSITE SURFACE
OVERALL LENGTH 0.860 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY 2 CONNECTOR
COAXIAL CONNECTOR SERIES DESIGNATION SMA
CONNECTION TYPE PER FUNCTION MALE INPUT AND
SPECIAL FEATURES GOLD PLATED BERLYIUM COPPER CONDUCTORS
III PRECIOUS MATERIAL GOLD
III PRECIOUS MATERIAL AND LOCATION CONDUCTOR SURFACE GOLD

Restrictions/Controls & Freight Information | NSN 5985-01-596-9565

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:GItem contains gold
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information