Product Details | DIPLEXER

5985-01-501-9757 An item designed to allow a single antenna to be used for simultaneous transmission and reception on different frequencies. It is installed in a transmission line or waveguide system between the transmitter(s) and/or receivers and a common antenna. It may have provisions for tuning.

Part Alternates: DFP102RW1, DFP-102RW-1, 5985-01-501-9757, 01-501-9757, 5985015019757, 015019757

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 22 OCT 2002 01-501-9757

Demand History | NSN 5985-01-501-9757

Part Number Request Date QTY Origin
DFP102RW1 2022-05-02 1 AU
5985-01-501-9757 2014-09-22 1 US
5985-01-501-9757 2014-09-22 1 US
5985-01-501-9757 2010-01-25 2 US

Cross Reference | NSN 5985-01-501-9757

Part Number Cage Code Manufacturer
DFP-102RW-1 55908 METROPOLE PRODUCTS, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-01-501-9757

Technical Data | NSN 5985-01-501-9757

Characteristic Specifications
DC VOLTAGE RATING 15.0 VOLTS NOMINAL
OPERATING FREQUENCY 292.0 MEGAHERTZ MINIMUM AND 400.0 MEGAHERTZ MAXIMUM
SPECIAL FEATURES DIPLEXER PREAMPLIFIER, WATERPROOF SATCOM DIPLEXER WITH INTERGRAL LOW NOISE AMP; RECEIVE CHARACTERISTICS - PASSBAND 243-270 MHZ, ROLLOFF OVER PASSBAND 1.5 DB MAX; TRANSMIT CHARACTERISTICS - INSERTION LOSS PASSBAND 0.7 DB MAX

Restrictions/Controls & Freight Information | NSN 5985-01-501-9757

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information