Product Details | RADIO FREQUENCY TRANSMISSION LINE SWITCH

5985-01-443-4973 An item specifically designed for mechanically or electronically positioning one or more radio frequency transmission line sections so as to couple it or them to other sections in a radio frequency transmission line system. The switching function may be operated by a manual actuator, an electromechanical actuator or by means of an arrangement of semiconductors and passive circuit devices. Excludes RELAY, (as modified).202593000005985000000

Part Alternates: NH185A4551, NH185A455-1, CSW38008, 185A4551, 185A455-1, 5985-01-443-4973, 01-443-4973, 5985014434973, 014434973

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 11 APR 1997 01-443-4973

Drawings & Photos | NSN 5985-01-443-4973


Cross Reference | NSN 5985-01-443-4973

Part Number Cage Code Manufacturer
185A455-1 03640 LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN
CSW38008 28983 DAICO INDUSTRIES, INC.
NH185A455-1 16236 DLA LAND AND MARITIME

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-01-443-4973

Technical Data | NSN 5985-01-443-4973

Characteristic Specifications
FREQUENCY RATING 50.0 MEGAHERTZ MINIMUM AND 250.0 MEGAHERTZ MAXIMUM SINGLE FREQUENCY OPERATING
INSERTION LOSS IN DECIBELS 1.30 SINGLE
ACTUATOR OPERATING METHOD SOLID STATE
SWITCH TYPE NONTRANSFER
COUPLING POSITION QUANTITY 8
TERMINAL TYPE AND QUANTITY 8 PIN
BODY STYLE 122B RECTANGULAR
OVERALL LENGTH 1.400 INCHES NOMINAL
OVERALL HEIGHT 0.150 INCHES NOMINAL
OVERALL WIDTH 1.000 INCHES NOMINAL
SPECIAL FEATURES NUCLEARHARDNESSCRITICALITEM
CRITICALITY CODE JUSTIFICATION FEAT
NUCLEAR HARDNESS CRITICAL FEATURE HARDENED

Restrictions/Controls & Freight Information | NSN 5985-01-443-4973

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:BESD sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:M The item is specifically designed to be or selected as being nuclear hard. In addition the item has other critical features such as tolerance, fit restrictions or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 723 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5985-01-443-4973

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each