Product Details | FIXED ATTENUATOR

5985-01-270-7051 A device for reducing the strength of an alternating current signal by a fixed or predetermined amount, without causing appreciable signal distortion, by maintaining correct impedance match.

Part Alternates: M3933/25-60S, M39332560S, A701M, MIL-A-3933/25, MILA393325, 10134436 , 21441951, 2144195-1, 5985-01-270-7051, 01-270-7051, 5985012707051, 012707051

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 12 JAN 1988 01-270-7051

Drawings & Photos | NSN 5985-01-270-7051


Demand History | NSN 5985-01-270-7051

Part Number Request Date QTY Origin
5985-01-270-7051 2024-02-60 59 DIBBS
5985-01-270-7051 2023-04-117 58 DIBBS
5985-01-270-7051 2022-09-261 24 DIBBS
5985-01-270-7051 2022-06-174 28 DIBBS
5985-01-270-7051 2022-06-166 22 DIBBS
5985-01-270-7051 2022-05-123 31 DIBBS
5985-01-270-7051 2022-04-108 31 DIBBS
5985-01-270-7051 2021-05-123 36 DIBBS
5985-01-270-7051 2021-04-101 36 DIBBS
5985-01-270-7051 2019-06-169 57 DIBBS
5985-01-270-7051 2018-09-263 42 DIBBS
5985-01-270-7051 2016-11-327 87 DIBBS
5985-01-270-7051 2016-02-39 48 DIBBS
5985-01-270-7051 2014-07-205 57 DIBBS
5985-01-270-7051 2013-02-58 44 DIBBS
5985-01-270-7051 2011-05-143 30 DIBBS
5985-01-270-7051 2009-09-245 47 DIBBS
5985-01-270-7051 2009-04-105 32 DIBBS
5985-01-270-7051 2008-11-309 40 DIBBS
5985-01-270-7051 2008-10-298 14 DIBBS

Cross Reference | NSN 5985-01-270-7051

Part Number Cage Code Manufacturer
2144195-1 55972 HONEYWELL INTL INC DEFENSE AVIONICS SYSTEMS
A701M 64537 AEROFLEX CONTROL COMPONENTS, INC. DBA AEROFLEX / KDI
M3933/25-60S 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-A-3933/25 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-01-270-7051

Technical Data | NSN 5985-01-270-7051

Characteristic Specifications
APPLICATION DESIGN TRANSMISSION LINE
INPUT IMPEDANCE RATING IN OHMS 50.0
OUTPUT IMPEDANCE RATING IN OHMS 50.0
FREQUENCY RANGE 0.000 GIGAHERTZ MINIMUM AND 18.000 GIGAHERTZ MAXIMUM
VOLTAGE STANDING WAVE RATIO 1.10 AND 1.15 AND 1.20 AND 1.25 AND 1.35
VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE 0.0 TO 2.0 GIGAHERTZ AND 2.0 TO 4.0 GIGAHERTZ AND 4.0 TO 8.0 GIGAHERTZ AND 8.0 TO 12.4 GIGAHERTZ AND 12.4 TO 18.0 GIGAHERTZ
RF SIGNAL ATTENUATION IN DECIBELS 1.0
POWER RATING 2.0 WATTS AVERAGE
OPERATING TEMP RANGE -55.0 TO 125.0 DEG CELSIUS
BODY STYLE 1B ROUND, TERMINAL/TERMINALS ON OPPOSITE SURFACES
OVERALL LENGTH 0.870 INCHES NOMINAL
OVERALL DIAMETER 0.317 INCHES NOMINAL
BODY MATERIAL STEEL
TERMINAL TYPE AND QUANTITY 2 CONNECTOR
COAXIAL CONNECTOR SERIES DESIGNATION SMA
CONNECTION TYPE PER FUNCTION FEMALE INPUT AND MALE OUTPUT
MOUNTING METHOD CONNECTOR
TEST DATA DOCUMENT 81349-MIL-A-3933 SPECIFICATION
SPECIFICATION/STANDARD DATA 81349-MIL-A-3933/25 GOVERNMENT SPECIFICATION
III UNPACKAGED UNIT WEIGHT 0.450 OUNCES
MANUFACTURERS CODE 81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MIL-A-3933/25
MANUFACTURERS CODE 81349
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE M3933/25-60S

Restrictions/Controls & Freight Information | NSN 5985-01-270-7051

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 060535 AERIAL/ANTENNAS DIRECTIONAL
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 723 unknown
Originating Activity Code TH Defense Supply Center Columbus
Columbus, OH 43215
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5985-01-270-7051

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesDDoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesDDoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each