Product Details | WAVEGUIDE ASSEMBLY

5985-01-221-2232 An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.

Part Alternates: V277B, X125A, X125ARAY2, X125A-RAY-2, 8876212, 887621-2, 5985-01-221-2232, 01-221-2232, 5985012212232, 012212232

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 26 NOV 1985 01-221-2232

Demand History | NSN 5985-01-221-2232

Part Number Request Date QTY Origin
5985-01-221-2232 2009-09-18 1 DIBBS
5985-01-221-2232 2009-06-15 1 DIBBS
5985-01-221-2232 2007-06-05 1 DIBBS
5985-01-221-2232 2007-03-26 1 DIBBS

Cross Reference | NSN 5985-01-221-2232

Part Number Cage Code Manufacturer
887621-2 3B150 RAYTHEON TECHNICAL SERVICES COMPANY LLC
887621-2 49956 RAYTHEON COMPANY DBA RAYTHEON
V277B 00416 VICTOR MICROWAVE, INC.
X125A 13047 MAURY MICROWAVE, INC.
X125A-RAY-2 13047 MAURY MICROWAVE, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-01-221-2232

Technical Data | NSN 5985-01-221-2232

Characteristic Specifications
MATERIAL COPPER ALLOY SINGLE TUBING SEGMENT AND FLANGE
FLANGE DEPTH 0.438 INCHES NOMINAL FIRST FLANGE
SURFACE TREATMENT RHODIUM AND SILVER FIRST TUBING SEGMENT AND FLANGE ALL SURFACES
NOMINAL THREAD SIZE 0.164 INCHES FIRST FLANGE ALL CONNECTION FACILITIES
STYLE DESIGNATOR BEND TYPE
FLANGE STYLE COVER TYPE SECOND FLANGE
WAVEGUIDE OFFSET DISTANCE 1.188 INCHES NOMINAL
FLANGE CONNECTING FACILITY AND QUANTITY 4 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES
TUBING WALL CONSTRUCTION STYLE SEAMLESS SINGLE TUBING SEGMENT
PRECIOUS MATERIAL AND LOCATION INT AND EXT SURFACES RHODIUM AND INT AND EXT SURFACES SILVER
SURFACE TREATMENT PAINT SECOND TUBING SEGMENT AND FLANGE OUTSIDE SURFACES
WAVEGUIDE OUTSIDE HEIGHT 0.500 INCHES NOMINAL
FLANGE OUTSIDE HEIGHT 1.625 INCHES NOMINAL FIRST FLANGE
THREAD DIRECTION RIGHT-HAND FIRST FLANGE ALL CONNECTION FACILITIES
FLANGE DEPTH 0.438 INCHES NOMINAL SECOND FLANGE
FLANGE INSIDE HEIGHT 0.505 INCHES NOMINAL SECOND FLANGE
FLEXIBILITY RIGID SINGLE TUBING SEGMENT
FLANGE OUTSIDE HEIGHT 1.625 INCHES NOMINAL SECOND FLANGE
BEND ANGLE IN DEG 90.0 SINGLE BEND E-PLANE
THREAD CLASS 2B FIRST FLANGE ALL CONNECTION FACILITIES
FLANGE CONNECTING FACILITY AND QUANTITY 4 THREADED HOLE FIRST FLANGE ALL CONNECTION FACILITIES
FLANGE OUTSIDE WIDTH 1.625 INCHES NOMINAL FIRST FLANGE
VOLTAGE STANDING WAVE RATIO 1.07
FLANGE INSIDE WIDTH 0.900 INCHES NOMINAL FIRST FLANGE
WAVEGUIDE INSIDE WIDTH 0.900 INCHES NOMINAL
FLANGE INSIDE WIDTH 1.005 INCHES NOMINAL SECOND FLANGE
CROSS-SECTIONAL SHAPE STYLE INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
FLANGE QUANTITY 2
FLANGE OUTSIDE WIDTH 1.625 INCHES NOMINAL SECOND FLANGE
FLANGE CONNECTING HOLE DIAMETER 0.169 INCHES NOMINAL SECOND FLANGE ALL CONNECTION FACILITIES
PRECIOUS MATERIAL RHODIUM AND SILVER
WAVEGUIDE OUTSIDE WIDTH 1.000 INCHES NOMINAL
WAVEGUIDE LONGER OFFSET DISTANCE 1.188 INCHES NOMINAL
FLANGE STYLE CHOKE TYPE FIRST FLANGE
THREAD SERIES DESIGNATOR UNC FIRST FLANGE ALL CONNECTION FACILITIES
WAVEGUIDE INSIDE HEIGHT 0.400 INCHES NOMINAL
FLANGE INSIDE DIAMETER 1.422 INCHES NOMINAL FIRST FLANGE
FLANGE INSIDE HEIGHT 0.400 INCHES NOMINAL FIRST FLANGE

Restrictions/Controls & Freight Information | NSN 5985-01-221-2232

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:CItem contains two or more precious metals
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063520 WAVEGUIDE IN BOXES/CRATES
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 723 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5985-01-221-2232

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each