NSN 5985-01-030-9983 SMC718810, SM-C-718810, 01-030-9983
Product Details | WAVEGUIDE ASSEMBLY
5985-01-030-9983 An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.
Part Alternates: SMC718810, SM-C-718810, 5985-01-030-9983, 01-030-9983, 5985010309983, 010309983
Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 16 NOV 1976 | 01-030-9983 | 00305 ( WAVEGUIDE ASSEMBLY ) |
Cross Reference | NSN 5985-01-030-9983
Part Number | Cage Code | Manufacturer |
---|---|---|
SM-C-718810 | 80063 | US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5985-01-030-9983
Technical Data | NSN 5985-01-030-9983
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | B2 BEND TYPE |
WAVEGUIDE LONGER OFFSET DISTANCE | 4.000 INCHES NOMINAL |
WAVEGUIDE OFFSET DISTANCE | 2.016 INCHES NOMINAL |
CROSS-SECTIONAL SHAPE STYLE | A1 INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
WAVEGUIDE OUTSIDE WIDTH | 1.359 INCHES NOMINAL |
WAVEGUIDE INSIDE WIDTH | 1.122 INCHES NOMINAL |
WAVEGUIDE INSIDE HEIGHT | 0.497 INCHES NOMINAL |
WAVEGUIDE OUTSIDE HEIGHT | 0.655 INCHES NOMINAL |
FLEXIBILITY | FLEXIBLE ALL TUBING SEGMENT |
TUBING WALL CONSTRUCTION STYLE | J9 CORRUGATED SINGLE TUBING SEGMENT |
MATERIAL | COPPER ALLOY ALL FLANGE |
SURFACE TREATMENT | SILVER ALL FLANGE INSIDE SURFACES ENAMEL ALL FLANGE OUTSIDE SURFACES |
FLANGE QUANTITY | 2 |
FLANGE STYLE | C28 COVER TYPE FIRST FLANGE C28 COVER TYPE SECOND FLANGE |
FLANGE INSIDE WIDTH | 1.253 INCHES NOMINAL FIRST FLANGE 1.253 INCHES NOMINAL SECOND FLANGE |
FLANGE INSIDE HEIGHT | 0.628 INCHES NOMINAL FIRST FLANGE 0.628 INCHES NOMINAL SECOND FLANGE |
FLANGE OUTSIDE WIDTH | 1.875 INCHES NOMINAL FIRST FLANGE 1.875 INCHES NOMINAL SECOND FLANGE |
FLANGE OUTSIDE HEIGHT | 1.875 INCHES NOMINAL FIRST FLANGE 1.875 INCHES NOMINAL SECOND FLANGE |
FLANGE DEPTH | 0.438 INCHES NOMINAL FIRST FLANGE 0.438 INCHES NOMINAL SECOND FLANGE |
FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE FIRST FLANGE SINGLE CONNECTION FACILITY 4 THREADED HOLE SECOND FLANGE SINGLE CONNECTION FACILITY |
FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES NOMINAL FIRST FLANGE SINGLE CONNECTION FACILITY |
THREAD SERIES DESIGNATOR | UNC SECOND FLANGE SINGLE CONNECTION FACILITY |
NOMINAL THREAD SIZE | 0.164 INCHES SECOND FLANGE SINGLE CONNECTION FACILITY |
THREAD CLASS | 2B SECOND FLANGE SINGLE CONNECTION FACILITY |
THREAD DIRECTION | RIGHT-HAND SECOND FLANGE SINGLE CONNECTION FACILITY |
VOLTAGE STANDING WAVE RATIO | 1.05 |
(NON-CORE DATA) TUBING MANUFACTURER PART NUMBER | SM-A-723237-5 ALL TUBING SEGMENT |
III PRECIOUS MATERIAL | SILVER |
III PRECIOUS MATERIAL AND LOCATION | FLANGE SURFACE SILVER |
MANUFACTURERS CODE | 80063 |
DESIGN CONTROL REFERENCE | SM-C-718810 |
Restrictions/Controls & Freight Information | NSN 5985-01-030-9983
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | S | Item contains silver |
Criticality Code: | N | The item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input). |
Category | Code | Description |
---|---|---|
NMF Description | 063520 | WAVEGUIDE IN BOXES/CRATES |
Less than car load rating | Q | 70 |
Less than truck load rating | W | Rating Variable |
Water commodity Code | 723 | unknown |
Originating Activity Code | CL | U.S. Army Communications-Electronics Fort Monmouth, NJ 07703-5006 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5985-01-030-9983
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | G | Communications and Electronics Equipment, Electronics Materiel |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | 4 | Communications Systems Agency and Satellite Communications |
Weapons Systems/End Item or Homogeneous Group | 4A | AN/FSC-78/GSC-39 |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | B16 | US Army Communications-Electronics Command and Fort Monmouth Fort Monmouth, NJ 07703-5016 |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Acquisition Advice Codes | X | SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 AY : Assembly |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9Y | Navy-owned stocks of material managed by the Army within the Army Communications and Electronics Materiel Readiness Command Naval Inventory Control Point, Mechanicsburg |
Source of Supply | B16 | US Army Communications-Electronics Command and Fort Monmouth Fort Monmouth, NJ 07703-5016 |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | X | SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 AY : Assembly |