Product Details | WAVEGUIDE SWITCH

5985-01-030-2379 An item specifically designed for mechanically or electronically positioning one or more waveguide sections so as to couple it or them to other sections in a waveguide system. The switching function may be operated by a manual actuator, an electromechanical actuator or by means of an arrangement of semiconductors and passive circuit devices. Excludes RELAY, (as modified).

Part Alternates: S2456, S-2456, 582R127H02, 5985-01-030-2379, 01-030-2379, 5985010302379, 010302379

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 30 OCT 1976 01-030-2379

Demand History | NSN 5985-01-030-2379

Part Number Request Date QTY Origin
582R127H02 2020-10-295 3 DIBBS
S-2456 2020-10-295 3 DIBBS

Cross Reference | NSN 5985-01-030-2379

Part Number Cage Code Manufacturer
582R127H02 97942 NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NORTHROP GRUMMAN SYSTEMS
S-2456 04426 ILLINOIS TOOL WORKS INC. DIV ILLINOIS TOOL WORKS
S-2456 12598 R L C ELECTRONICS, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-01-030-2379

Technical Data | NSN 5985-01-030-2379

Characteristic Specifications
VOLTAGE STANDING WAVE RATIO 1.30 1ST 1.80 2ND
INSERTION LOSS IN DECIBELS 0.30 1ST 0.60 2ND
MINIMUM CROSSTALK RATING IN DECIBELS 60.0 SINGLE
TERMINAL TYPE AND QUANTITY 4 CONNECTOR, RECEPTACLE
SWITCHING TIME 15.0 MILLISECONDS
OVERALL HEIGHT 1.812 INCHES NOMINAL
OVERALL WIDTH 2.000 INCHES NOMINAL
SPECIAL FEATURES SELECTED ITEM
MANUFACTURERS CODE 97942
DESIGN CONTROL REFERENCE 582R127H02

Restrictions/Controls & Freight Information | NSN 5985-01-030-2379

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TG Warner-Robins Air Logistics Center
Robins AFB, GA 31098-5609
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5985-01-030-2379

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeCWTG:AIRBORNE RADAR AND MISCELLANEOUS ELECTRONIC EQUIPMENT
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each