Product Details | WAVEGUIDE SWITCH

5985-00-931-2564 An item specifically designed for mechanically or electronically positioning one or more waveguide sections so as to couple it or them to other sections in a waveguide system. The switching function may be operated by a manual actuator, an electromechanical actuator or by means of an arrangement of semiconductors and passive circuit devices. Excludes RELAY, (as modified).

Part Alternates: 201773P1, 25155781, 2515578-1, 5985-00-931-2564, 00-931-2564, 5985009312564, 009312564

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 14 SEP 1966 00-931-2564

Cross Reference | NSN 5985-00-931-2564

Part Number Cage Code Manufacturer
201773P1 01456 MICROWAVE DEVELOPMENT LABORATORIES, INC.
2515578-1 10001 NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-00-931-2564

Technical Data | NSN 5985-00-931-2564

Characteristic Specifications
RF POWER HANDLING CAPABILITY 7.0 KILOWATTS AVERAGE SINGLE
MINIMUM CROSSTALK RATING IN DECIBELS 100.0 SINGLE
ACTUATOR OPERATING METHOD RELAY
ACTUATOR CURRENT TYPE AND RATING IN AMPS 1.0 DC NOMINAL
ACTUATOR VOLTAGE IN VOLTS 48.0 MINIMUM AND 52.0 MAXIMUM
SWITCH TYPE NONTRANSFER
POLE QUANTITY 1
THROW QUANTITY 1
COUPLING POSITION QUANTITY 3
SWITCHING TIME 250.0 MILLISECONDS
FLANGE CONNECTING FACILITY AND QUANTITY 12 THREADED HOLE
OVERALL LENGTH 6.000 INCHES MAXIMUM
OVERALL HEIGHT 2.937 INCHES NOMINAL
OVERALL WIDTH 4.219 INCHES NOMINAL
THREAD SERIES DESIGNATOR UNC FLANGE CONNECTION FACILITY HOLE UNC MOUNTING FACILITY HOLE
NOMINAL THREAD SIZE 0.164 INCHES FLANGE CONNECTION FACILITY HOLE 0.164 INCHES MOUNTING FACILITY HOLE
MANUFACTURERS CODE 10001
MFR SOURCE CONTROLLING REFERENCE 2515578-1

Restrictions/Controls & Freight Information | NSN 5985-00-931-2564

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code HH Navy ICP
Mechanicsburg, PA 17055-0788
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5985-00-931-2564

Category Code Description
Cognizance Codes7HDepot level reparable shipboard and base equipment, assemblies, components and repair parts related to Naval Sea Systems Command equipment
Naval Inventory Control Point, Mechanicsburg
Special Material Content3 Electrostatic Discharge (ESD)/Sensitive Item
Source of SupplyNRPNAVICP-ERP
700 Robbins Avenue
Philadelphia, PA 19111-5098
AgencyDNDepartment of the Navy
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityHDepot Level Reparable
Acquisition Advice CodesPRESTRICTED REQUISITION - SECURITY ASSISTANCE PROGRAM (SAP) 1. Indicates item is stocked or acquired only for SAP (replaces Military Assistance Program (MAP)) requirements, or 2. Indicates item is nonstocked and materiel is ordered from the contractor for shipment directly to the foreign government. 3. Base, post, camp, or station will not requisition.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative