Product Details | WAVEGUIDE SWITCH

5985-00-902-6866 An item specifically designed for mechanically or electronically positioning one or more waveguide sections so as to couple it or them to other sections in a waveguide system. The switching function may be operated by a manual actuator, an electromechanical actuator or by means of an arrangement of semiconductors and passive circuit devices. Excludes RELAY, (as modified).

Part Alternates: A25A914312101, A25A914-312-101, D10205G1, RAM272, 5985-00-902-6866, 00-902-6866, 5985009026866, 009026866

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1960 00-902-6866

Cross Reference | NSN 5985-00-902-6866

Part Number Cage Code Manufacturer
A25A914-312-101 99696 LOCKHEED MARTIN CORPORATION DIV LOCKHEED MARTIN SYSTEMS & GLOBAL
D10205G1 06351 MICROWAVE ENGINEERING CORPORATION
D10205G1 23372 LUCAS AEROSPACE COMMUNICATIONS AND ELECTRONICS INC
RAM272 00443 WAVELINE INCORPORATED

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-00-902-6866

Technical Data | NSN 5985-00-902-6866

Characteristic Specifications
RF POWER HANDLING CAPABILITY 900.0 WATTS PEAK SINGLE
INSERTION LOSS IN DECIBELS 0.50 SINGLE
MINIMUM CROSSTALK RATING IN DECIBELS 50.0 SINGLE
ACTUATOR OPERATING METHOD RELAY
ACTUATOR CURRENT TYPE AND RATING IN AMPS 0.25 DC NOMINAL
ACTUATOR VOLTAGE IN VOLTS 28.0 NOMINAL
SWITCH TYPE TRANSFER
COUPLING POSITION QUANTITY 5
TERMINAL TYPE AND QUANTITY 1 CONNECTOR, RECEPTACLE AND 4 RECTANGULAR FLANGE
SWITCHING TIME 0.15 SECONDS
WAVEGUIDE FLANGE TYPE CHOKE
FLANGE CONNECTING FACILITY AND QUANTITY 4 THREADED HOLE
OVERALL LENGTH 3.781 INCHES MAXIMUM
OVERALL HEIGHT 2.250 INCHES NOMINAL
OVERALL WIDTH 3.187 INCHES NOMINAL
THREAD SERIES DESIGNATOR UNC FLANGE CONNECTION FACILITY HOLE UNC MOUNTING FACILITY HOLE
NOMINAL THREAD SIZE 0.164 INCHES FLANGE CONNECTION FACILITY HOLE 0.164 INCHES MOUNTING FACILITY HOLE
III OPERATING TEMP RANGE -54.0 TO 100.0 DEG CELSIUS

Restrictions/Controls & Freight Information | NSN 5985-00-902-6866

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5985-00-902-6866

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each