NSN 5985-00-840-2394 M0D905DC1GC, C89201, C89-201
Product Details | VARIABLE ATTENUATOR
5985-00-840-2394 A device for reducing the strength of an alternating current signal either continuously or in steps, without causing appreciable signal distortion, by maintaining substantially constant output and/or input impedance match. Continuously variable resistive devices must consist of at least two sections or one section with at least two rotating contacts. The item must have an overall attenuation rating. Includes tandem mounted variable resistors designed to function as an attenuator but whose terminals are not connected. See also RESISTOR, VAIABLE (as modified).
Part Alternates: M0D905DC1GC, C89201, C89-201, 7238519, 723851-9, 905, 5985-00-840-2394, 00-840-2394, 5985008402394, 008402394
Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 16 DEC 1966 | 00-840-2394 | 00838 ( ATTENUATOR, VARIABLE ) |
Demand History | NSN 5985-00-840-2394
Part Number | Request Date | QTY | Origin |
---|---|---|---|
5985-00-840-2394 | 2008-08-231 | 5 | DIBBS |
5985-00-840-2394 | 2008-08-226 | 4 | DIBBS |
5985-00-840-2394 | 2007-05-127 | 5 | DIBBS |
5985-00-840-2394 | 2006-07-184 | 3 | DIBBS |
5985-00-840-2394 | 2006-04-109 | 2 | DIBBS |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5985-00-840-2394
Technical Data | NSN 5985-00-840-2394
Characteristic | Specifications |
---|---|
APPLICATION DESIGN | TRANSMISSION LINE |
FREQUENCY RANGE | 0.000 HERTZ MINIMUM AND 1.000 GIGAHERTZ MAXIMUM |
IMPEDANCE RATING IN OHMS | 50.0 INPUT-OUTPUT |
VOLTAGE STANDING WAVE RATIO | 1.50 |
POWER RATING | 2.0 WATTS PEAK |
INSERTION LOSS AT MINIMUM ATTENUATION IN MAXIMUM DECIBELS | 0.8 |
OVERALL ATTENUATION RANGE IN DECIBELS | 0.5 TO 10.0 |
OVERALL ATTENUATION ACCURACY IN DECIBELS | -0.20 TO 0.20 |
ATTENUATION VARIATION METHOD | CONTINUOUS |
BODY STYLE | 11A COAXIAL TYPE |
OVERALL LENGTH | 6.875 INCHES MINIMUM AND 7.000 INCHES MAXIMUM |
OVERALL HEIGHT | 2.940 INCHES MAXIMUM |
OVERALL WIDTH | 5.438 INCHES MINIMUM AND 5.562 INCHES MAXIMUM |
ADJUSTMENT DEVICE TYPE AND QUANTITY | 1 KNOB |
TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, COAXIAL, MALE AND 1 CONNECTOR, COAXIAL, FEMALE |
COAXIAL CONNECTOR SERIES DESIGNATION | N |
MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED STUD |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
MOUNTING FACILITY NOMINAL SCREW THREAD DIAMETER | 0.190 INCHES |
MOUNTING THREAD QUANTITY | 32 PER INCH |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.250 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.500 INCHES NOMINAL |
III SCALE LINEARITY | NONLINEAR |
III SCALE DIVISION QUANTITY | 50 |
Restrictions/Controls & Freight Information | NSN 5985-00-840-2394
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | D | Munitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.) |
Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | ||
Less than truck load rating | J | 100.2 |
Water commodity Code | 658 | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5985-00-840-2394
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | Q | Electronics Materiel (DLA/GSA Items) |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 00 | DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 1R | Aeronautical, photographic, and meteorological material (consumable or expense type material) Naval Inventory Control Point, Philadelphia |
Special Material ID | EE | SPECIAL ELECTRONICAIRCRAFT(E2C) |
Special Material Content | 2 | Electrostatic Discharge (ESD)/Electromagnetic (EM) Sensitive Item |
Source of Supply | NRP | NAVICP-ERP 700 Robbins Avenue Philadelphia, PA 19111-5098 |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Reparability | W | Ground Support Equipment-End Items |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |