Product Details | WAVEGUIDE SWITCH

5985-00-760-1329 An item specifically designed for mechanically or electronically positioning one or more waveguide sections so as to couple it or them to other sections in a waveguide system. The switching function may be operated by a manual actuator, an electromechanical actuator or by means of an arrangement of semiconductors and passive circuit devices. Excludes RELAY, (as modified).

Part Alternates: A25A409006, A25A409-006, A25A409006101, A25A409-006-101, 0571, 0571C, 5985-00-760-1329, 00-760-1329, 5985007601329, 007601329

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1960 00-760-1329

Cross Reference | NSN 5985-00-760-1329

Part Number Cage Code Manufacturer
0571 96341 COBHAM ELECTRONIC SYSTEMS INC. DBA COBHAM DEFENSE ELECTRONICS
0571C 96341 COBHAM ELECTRONIC SYSTEMS INC. DBA COBHAM DEFENSE ELECTRONICS
A25A409-006 99696 LOCKHEED MARTIN CORPORATION DIV LOCKHEED MARTIN SYSTEMS & GLOBAL
A25A409-006-101 99696 LOCKHEED MARTIN CORPORATION DIV LOCKHEED MARTIN SYSTEMS & GLOBAL
A25A409006 99696 LOCKHEED MARTIN CORPORATION DIV LOCKHEED MARTIN SYSTEMS & GLOBAL

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-00-760-1329

Technical Data | NSN 5985-00-760-1329

Characteristic Specifications
RF POWER HANDLING CAPABILITY 150.0 WATTS AVERAGE 1ST 60.0 KILOWATTS PEAK 2ND
INSERTION LOSS IN DECIBELS 0.50 SINGLE
MINIMUM CROSSTALK RATING IN DECIBELS 20.0 SINGLE
ACTUATOR OPERATING METHOD RELAY
RF MAXIMUM VOLTAGE RATING 22.5 VOLTS PEAK
TERMINAL TYPE AND QUANTITY 3 RECTANGULAR FLANGE
SWITCHING TIME 1.0 SECONDS
OVERALL LENGTH 6.250 INCHES NOMINAL
OVERALL HEIGHT 2.600 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5985-00-760-1329

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5985-00-760-1329

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each