NSN 5985-00-485-4881 AC06T, AC-06T, 00-485-4881
Product Details | FIXED ATTENUATOR
5985-00-485-4881 A device for reducing the strength of an alternating current signal by a fixed or predetermined amount, without causing appreciable signal distortion, by maintaining correct impedance match.
Part Alternates: AC06T, AC-06T, 5985-00-485-4881, 00-485-4881, 5985004854881, 004854881
Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 30 MAY 1969 | 00-485-4881 | 14224 ( ATTENUATOR, FIXED ) |
Cross Reference | NSN 5985-00-485-4881
Part Number | Cage Code | Manufacturer |
---|---|---|
AC-06T | 00929 | MICROLAB/FXR |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5985-00-485-4881
Related Products | NSN 5985-00-485-4881
Technical Data | NSN 5985-00-485-4881
Characteristic | Specifications |
---|---|
APPLICATION DESIGN | TRANSMISSION LINE |
INPUT IMPEDANCE RATING IN OHMS | 50.0 |
OUTPUT IMPEDANCE RATING IN OHMS | 50.0 |
FREQUENCY RANGE | 4.500 GIGAHERTZ MINIMUM AND 10.000 GIGAHERTZ MAXIMUM |
VOLTAGE STANDING WAVE RATIO | 1.35 |
RF SIGNAL ATTENUATION IN DECIBELS | 6.0 |
ATTENUATION ACCURACY IN DECIBELS | -0.80 TO 0.80 |
FREQUENCY SENSITIVITY ATTENUATION IN DECIBELS | NOT RATED |
POWER RATING | 3.0 WATTS AVERAGE |
OPERATING TEMP RANGE | -55.0 TO 125.0 DEG CELSIUS |
TEMPERATURE SENSITIVITY ATTENUATION IN DECIBELS | NOT RATED |
BODY STYLE | 1B ROUND, TERMINAL/TERMINALS ON OPPOSITE SURFACES |
OVERALL LENGTH | 3.000 INCHES NOMINAL |
OVERALL DIAMETER | 0.606 INCHES NOMINAL |
BODY MATERIAL | COPPER |
BODY SURFACE TREATMENT | NICKEL PLATED |
TERMINAL TYPE AND QUANTITY | 2 CONNECTOR |
COAXIAL CONNECTOR SERIES DESIGNATION | TNC |
MOUNTING METHOD | CONNECTOR |
Restrictions/Controls & Freight Information | NSN 5985-00-485-4881
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 060535 | AERIAL/ANTENNAS DIRECTIONAL |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 723 | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5985-00-485-4881
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | Q | Electronics Materiel (DLA/GSA Items) |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 00 | DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |