Product Details | RADIO FREQUENCY TRANSMISSION LINE SWITCH

5985-00-482-0495 An item specifically designed for mechanically or electronically positioning one or more radio frequency transmission line sections so as to couple it or them to other sections in a radio frequency transmission line system. The switching function may be operated by a manual actuator, an electromechanical actuator or by means of an arrangement of semiconductors and passive circuit devices. Excludes RELAY, (as modified).202593000005985000000

Part Alternates: SA90N104, SA90N10-4, 10110432, 5985-00-482-0495, 00-482-0495, 5985004820495, 004820495

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 21 SEP 1970 00-482-0495

Drawings & Photos | NSN 5985-00-482-0495


Demand History | NSN 5985-00-482-0495

Part Number Request Date QTY Origin
5985-00-482-0495 2015-01-20 5 United States
5985-00-482-0495 2014-06-10 1 US
5985-00-482-0495 2013-09-23 2 United States
10110432 2013-07-18 4 US
5985-00-482-0495 2008-01-19 2 South Korea

Cross Reference | NSN 5985-00-482-0495

Part Number Cage Code Manufacturer
10110432 0VZN2 OAKS DIVERSIFIED INDUSTRIES INC
10110432 18876 U S ARMY AVIATION AND MISSILE COMMAND
SA90N10-4 24022 TELEDYNE WIRELESS, LLC DBA TELEDYNE MICROWAVE SOLUTIONS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-00-482-0495

Technical Data | NSN 5985-00-482-0495

Characteristic Specifications
FREQUENCY RATING 1.25 GIGAHERTZ MINIMUM AND 1.35 GIGAHERTZ MAXIMUM SINGLE FREQUENCY OPERATING 1.25 GIGAHERTZ MINIMUM AND 1.35 GIGAHERTZ MAXIMUM SINGLE FREQUENCY RF POWER HANDLING 1.25 GIGAHERTZ MINIMUM AND 1.35 GIGAHERTZ MAXIMUM SINGLE FREQUENCY VOLTAGE STANDING WAVE RATIO 1.25 GIGAHERTZ MINIMUM AND 1.35 GIGAHERTZ MAXIMUM SINGLE FREQUENCY INSERTION LOSS REFERENCE 1.25 GIGAHERTZ MINIMUM AND 1.35 GIGAHERTZ MAXIMUM SINGLE FREQUENCY CROSSTALK REFERENCE
RF POWER HANDLING CAPABILITY 100.0 WATTS PEAK SINGLE
VOLTAGE STANDING WAVE RATIO 1.30 SINGLE
INSERTION LOSS IN DECIBELS 0.30 SINGLE
MINIMUM CROSSTALK RATING IN DECIBELS 50.0 SINGLE
ACTUATOR OPERATING METHOD RELAY
ACTUATOR CURRENT TYPE AND RATING IN AMPS 0.33 DC MAXIMUM
ACTUATOR VOLTAGE IN VOLTS 28.0 NOMINAL
RF MAXIMUM VOLTAGE RATING 1.0 KILOVOLTS RMS
SWITCH TYPE NONTRANSFER
POLE QUANTITY 1
THROW QUANTITY 2
COUPLING POSITION QUANTITY 4
TERMINAL TYPE AND QUANTITY 1 PLUG, COAXIAL AND 2 RECEPTACLE, COAXIAL
COAXIAL CONNECTOR SERIES DESIGNATION N AND N
CONNECTOR END DESIGN FEMALE AND MALE
SWITCH OPERATION SEQUENCE BREAKS BEFORE MAKES
SWITCHING TIME 10.0 MILLISECONDS
SWITCH RETURN MECHANISM TYPE FAIL-SAFE
BODY STYLE 28B IRREGULAR
OVERALL LENGTH 2.250 INCHES NOMINAL
OVERALL HEIGHT 1.850 INCHES NOMINAL
OVERALL WIDTH 1.940 INCHES NOMINAL
MATERIAL METAL BODY
SURFACE TREATMENT NICKEL BODY OUTSIDE SURFACES
MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED HOLE
MOUNTING FACILITY PATTERN TWO POSITION DIAGONAL SINGLE MOUNTING FACILITY PATTERN
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS 0.585 INCHES NOMINAL SINGLE MOUNTING FACILITY PATTERN
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS 0.505 INCHES NOMINAL SINGLE MOUNTING FACILITY PATTERN
THREAD SERIES DESIGNATOR UNC MOUNTING FACILITY HOLE
NOMINAL THREAD SIZE 0.138 INCHES MOUNTING FACILITY HOLE
THREAD CLASS 2B MOUNTING FACILITY HOLE
III OPERATING TEMP RANGE -55.0 TO 85.0 DEG CELSIUS

Restrictions/Controls & Freight Information | NSN 5985-00-482-0495

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 723 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5985-00-482-0495

Category Code Description
Materiel Category and Inventory ManagerQ Electronics Materiel (DLA/GSA Items)
Appropriation and Budget Activity2 Stock Fund Secondary Items
Management Inventory Segment2 NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable.
Specific Group/Generic Code0 Medical Materiel
Weapons Systems/End Item or Homogeneous Group00DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item
Accounting Requirements CodeX Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDADepartment of the Army
Service OrganizationAU.S. Army
ReparabilityZThis is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item.
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each