NSN 5985-00-241-8599 MDC110210, MDC1102-10, MDC1102A10
Product Details | FIXED ATTENUATOR
5985-00-241-8599 A device for reducing the strength of an alternating current signal by a fixed or predetermined amount, without causing appreciable signal distortion, by maintaining correct impedance match.
Part Alternates: MDC110210, MDC1102-10, MDC1102A10, MDC1102A-10, 20038, 204310, 2043-10, 76810, 768-10, 5985-00-241-8599, 00-241-8599, 5985002418599, 002418599
Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 27 JUN 1969 | 00-241-8599 | 14224 ( ATTENUATOR, FIXED ) |
Demand History | NSN 5985-00-241-8599
Part Number | Request Date | QTY | Origin |
---|---|---|---|
20038 | 2024-03-64 | 2 | DIBBS |
2043-10 | 2024-03-64 | 2 | DIBBS |
768-10 | 2024-03-64 | 2 | DIBBS |
MDC1102A-10 | 2024-03-64 | 2 | DIBBS |
20038 | 2024-02-52 | 2 | DIBBS |
2043-10 | 2024-02-52 | 2 | DIBBS |
768-10 | 2024-02-52 | 2 | DIBBS |
MDC1102A-10 | 2024-02-52 | 2 | DIBBS |
20038 | 2021-03-70 | 4 | DIBBS |
2043-10 | 2021-03-70 | 4 | DIBBS |
768-10 | 2021-03-70 | 4 | DIBBS |
MDC1102A-10 | 2021-03-70 | 4 | DIBBS |
20038 | 2020-09-259 | 2 | DIBBS |
2043-10 | 2020-09-259 | 2 | DIBBS |
768-10 | 2020-09-259 | 2 | DIBBS |
MDC1102A-10 | 2020-09-259 | 2 | DIBBS |
5985-00-241-8599 | 2018-12-343 | 1 | DIBBS |
5985-00-241-8599 | 2017-05-129 | 2 | DIBBS |
5985-00-241-8599 | 2017-03-89 | 2 | DIBBS |
5985-00-241-8599 | 2013-10-290 | 1 | DIBBS |
5985-00-241-8599 | 2013-10-275 | 1 | DIBBS |
5985-00-241-8599 | 2008-11-316 | 1 | US |
Cross Reference | NSN 5985-00-241-8599
Part Number | Cage Code | Manufacturer |
---|---|---|
20038 | 0H3E9 | NVISION INDUSTRIES, INC. DBA WEINSCHEL ASSOCIATES |
2043-10 | 64671 | AEROFLEX / INMET, INC. DBA INMET |
768-10 | 99899 | L-3 COMMUNICATIONS CORPORATION DBA NARDA MICROWAVE EAST |
MDC1102-10 | 52335 | DAL-TECH DEVICES, INC. DBA MICROWAVE DISTRIBUTORS COMPANY |
MDC1102A-10 | 52335 | DAL-TECH DEVICES, INC. DBA MICROWAVE DISTRIBUTORS COMPANY |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5985-00-241-8599
Related Products | NSN 5985-00-241-8599
Technical Data | NSN 5985-00-241-8599
Characteristic | Specifications |
---|---|
APPLICATION DESIGN | TRANSMISSION LINE |
INPUT IMPEDANCE RATING IN OHMS | 50.0 |
OUTPUT IMPEDANCE RATING IN OHMS | 50.0 |
FREQUENCY RANGE | 0.000 HERTZ MINIMUM AND 11.000 GIGAHERTZ MAXIMUM |
VOLTAGE STANDING WAVE RATIO | 1.10 AND 1.15 AND 1.20 AND 1.30 |
VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE | 0.0 TO 1.0 GIGAHERTZ AND 1.0 TO 4.0 GIGAHERTZ AND 4.0 TO 6.0 GIGAHERTZ AND 6.0 TO 11.0 GIGAHERTZ |
RF SIGNAL ATTENUATION IN DECIBELS | 10.0 |
ATTENUATION ACCURACY IN DECIBELS | -0.75 TO 0.75 |
ATTENUATION ACCURACY REFERENCE FREQUENCY | 11.0 GIGAHERTZ |
FREQUENCY SENSITIVITY ATTENUATION IN DECIBELS | NOT RATED |
POWER RATING | 20.0 WATTS AVERAGE |
OPERATING TEMP RANGE | ANY ACCEPTABLE |
TEMPERATURE SENSITIVITY ATTENUATION IN DECIBELS | NOT RATED |
BODY STYLE | 1B ROUND, TERMINAL/TERMINALS ON OPPOSITE SURFACES |
OVERALL LENGTH | 3.313 INCHES NOMINAL |
OVERALL DIAMETER | 1.500 INCHES NOMINAL |
BODY MATERIAL | CHROMIUM-NICKEL-ALLOY STEEL |
TERMINAL TYPE AND QUANTITY | 2 CONNECTOR |
COAXIAL CONNECTOR SERIES DESIGNATION | N |
CONNECTION TYPE PER FUNCTION | FEMALE INPUT AND MALE OUTPUT |
MOUNTING METHOD | CONNECTOR |
III UNPACKAGED UNIT WEIGHT | 5.600 OUNCES |
III FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
Restrictions/Controls & Freight Information | NSN 5985-00-241-8599
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | B | Munitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.) |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 060535 | AERIAL/ANTENNAS DIRECTIONAL |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 723 | unknown |
Originating Activity Code | SG | 403 SCMS/GUED 5215 Thurlow St, Suite 5, Bldg 70C Wright-Patterson AFB OH 45433 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5985-00-241-8599
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | Q | Electronics Materiel (DLA/GSA Items) |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 00 | DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Budget Code | 9 | General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors. |
Materiel Management Aggregation Code | EH | SX:ELECTRONIC COMPONENTS |
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DF | Department of the Air Force |
Service Organization | F | U.S. Air Force |
Reparability | N | Stock Fund (except Munitions) |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |