NSN 5985-00-238-9435 ABJ76, B2345020000, B234502-0000
Product Details | FIXED ATTENUATOR
5985-00-238-9435 A device for reducing the strength of an alternating current signal by a fixed or predetermined amount, without causing appreciable signal distortion, by maintaining correct impedance match.
Part Alternates: ABJ76, B2345020000, B234502-0000, CN1288/U, CN1288U, FP503DB, FP50-3DB, FP503DBBNC, FP50-3DBBNC, FP503N, FP50-3N, 1001FP503N, 1001FP50-3N, 18014453, 1801445-3, 192396, 192-396, 2345020000, 234502-0000, 51217-1003, 5985-00-238-9435, 00-238-9435, 5985002389435, 002389435, 512171003
Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 05 NOV 1969 | 00-238-9435 | 14224 ( ATTENUATOR, FIXED ) |
Cross Reference | NSN 5985-00-238-9435
Part Number | Cage Code | Manufacturer |
---|---|---|
1001FP50-3N | 23042 | TRILITHIC, INC. |
1801445-3 | 21877 | NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NAVAL AND MARINE SYSTEMS |
192-396 | 90073 | CMC ELECTRONICS INC |
234502-0000 | 30184 | BUTLER NATIONAL CORP |
51217-1003 | 65597 | THALES DEFENSE & SECURITY, INC. |
ABJ76 | 00929 | MICROLAB/FXR |
B234502-0000 | 30184 | BUTLER NATIONAL CORP |
CN1288/U | 80058 | JOINT ELECTRONICS TYPE DESIGNATION SYSTEM |
FP50-3DB | 23042 | TRILITHIC, INC. |
FP50-3DBBNC | 23042 | TRILITHIC, INC. |
FP50-3N | 23042 | TRILITHIC, INC. |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5985-00-238-9435
Related Products | NSN 5985-00-238-9435
Technical Data | NSN 5985-00-238-9435
Characteristic | Specifications |
---|---|
APPLICATION DESIGN | TRANSMISSION LINE |
SCHEMATIC DIAGRAM DESIGNATOR | 1A C |
INPUT IMPEDANCE RATING IN OHMS | 50.0 |
OUTPUT IMPEDANCE RATING IN OHMS | 50.0 |
FREQUENCY RANGE | NOT RATED |
VOLTAGE STANDING WAVE RATIO | NOT RATED |
RF SIGNAL ATTENUATION IN DECIBELS | 3.0 |
ATTENUATION ACCURACY IN DECIBELS | NOT RATED |
FREQUENCY SENSITIVITY ATTENUATION IN DECIBELS | NOT RATED |
TEMPERATURE SENSITIVITY ATTENUATION IN DECIBELS | NOT RATED |
OVERALL LENGTH | 2.000 INCHES NOMINAL |
OVERALL DIAMETER | 0.500 INCHES NOMINAL |
TERMINAL TYPE AND QUANTITY | 2 CONNECTOR |
MOUNTING METHOD | TERMINAL |
MANUFACTURERS CODE | 23042 |
DESIGN CONTROL REFERENCE | FP50-3DB |
Restrictions/Controls & Freight Information | NSN 5985-00-238-9435
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | D | Munitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.) |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | M | 85 |
Less than truck load rating | W | Rating Variable |
Water commodity Code | 658 | unknown |
Originating Activity Code | CL | U.S. Army Communications-Electronics Fort Monmouth, NJ 07703-5006 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5985-00-238-9435
Category | Code | Description |
---|---|---|
Cognizance Codes | 9Y | Navy-owned stocks of material managed by the Army within the Army Communications and Electronics Materiel Readiness Command Naval Inventory Control Point, Mechanicsburg |
Source of Supply | B16 | US Army Communications-Electronics Command and Fort Monmouth Fort Monmouth, NJ 07703-5016 |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |