NSN 5980-01-229-7417 HCPL2731, HCPL-2731, HP900732
Product Details | OPTOELECTRONIC COUPLER
5980-01-229-7417 A device containing one or more light sources (either incandescent, glow, or solid state, lamps) opticallycoupled to one or more semiconductor type photo-sensitive elements, all of which are contained in an opaque enclosure. Light generated within the device by the application of an appropriate electrical input to the light source(s) acts upon the light sensor(s) to produce a corresponding output or change in some electrical quantity or variation in some electrical property. For items in which the light in directed at another item and the reflected light is interpreted (read) see SCANNER, OPTICAL.
Part Alternates: HCPL2731, HCPL-2731, HP900732, QCPL2745, D18625200, D-1862-5200, 19900732, 1990-0732, 302110, 302-110, 5980-01-229-7417, 01-229-7417, 5980012297417, 012297417
Electrical and Electronic Equipment Components | Optoelectronic Devices and Associated Hardware
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 04 APR 1986 | 01-229-7417 | 62335 ( COUPLER, OPTOELECTRONIC ) |
Cross Reference | NSN 5980-01-229-7417
Part Number | Cage Code | Manufacturer |
---|---|---|
1990-0732 | 24539 | AGILENT TECHNOLOGIES INC. DIV SEMICONDUCTOR PRODUCTS GROUP |
1990-0732 | 28480 | HEWLETT-PACKARD COMPANY DBA HEWLETT-PACKARD CO. OR HP |
302-110 | FA0Q5 | RS COMPONENTS SAS |
D-1862-5200 | D1870 | ROCKWELL-COLLINS DEUTSCHLAND GESCHAEFTSBEREICH DER ROCKWELL INTER |
HCPL-2731 | 24539 | AGILENT TECHNOLOGIES INC. DIV SEMICONDUCTOR PRODUCTS GROUP |
HCPL-2731 | 28480 | HEWLETT-PACKARD COMPANY DBA HEWLETT-PACKARD CO. OR HP |
HP900732 | 24539 | AGILENT TECHNOLOGIES INC. DIV SEMICONDUCTOR PRODUCTS GROUP |
HP900732 | 28480 | HEWLETT-PACKARD COMPANY DBA HEWLETT-PACKARD CO. OR HP |
QCPL2745 | 24539 | AGILENT TECHNOLOGIES INC. DIV SEMICONDUCTOR PRODUCTS GROUP |
QCPL2745 | 28480 | HEWLETT-PACKARD COMPANY DBA HEWLETT-PACKARD CO. OR HP |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5980-01-229-7417
Technical Data | NSN 5980-01-229-7417
Characteristic | Specifications |
---|---|
GENERAL CHARACTERISTICS ITEM DESCRIPTION | DUAL LOW INPUT CURRENT HIGH GAIN OPTOCOUPLER; REVERSE INPUT VOLTAGE EACH CHANNEL 5.0 V; PEAK INPUT CURRENT IF EACH CHANNEL 40.0 MA; INPUT POWER DISSIPATION 35.0 MW; OPERATING TEMPERATURE RANGE FROM MINUS 40.0 DEGREE CELSIUS TO PLUS 85.0 DEGREE CELSIUS; 0.390 IN. MAX LG; 0.260 IN. MAX W; 0.185 IN. MAX H; EIGHT PIN TYPE TERMINALS 0.115 IN. MIN LG |
III STORAGE TEMP RANGE | -55.0 TO 125.0 DEG CELSIUS |
III END ITEM IDENTIFICATION | LOS ANGELES CLASS SSN (688); VARIOUS SHORE ATC; AN/BQH-5 SONAR DATA COLLECTING SET; INTEGRATED UNDERWATER SURVEILLANCE SYSTEMS |
Restrictions/Controls & Freight Information | NSN 5980-01-229-7417
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | Q | Strategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.” |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Electro-static Discharge Susceptible: | B | ESD sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061680 | ELEC WIRING PLUGS ETC |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 72D | unknown |
Originating Activity Code | TH | Defense Supply Center Columbus Columbus, OH 43215 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | 3 | Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices). |
Management | NSN 5980-01-229-7417
Category | Code | Description |
---|---|---|
Budget Code | 9 | General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors. |
Materiel Management Aggregation Code | EH | SX:ELECTRONIC COMPONENTS |
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DF | Department of the Air Force |
Service Organization | F | U.S. Air Force |
Reparability | N | Stock Fund (except Munitions) |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
Combat Essentiality Code | 5 | Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency. |
Materiel Management Code | B | All CommoditiesDefense Logistics Agency, (DLA,) |
Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DM | U.S. Marine Corps |
Service Organization | M | U.S. Marine Corps |
Reparability | Z | Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code. |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |