Product Details | ELECTRICAL CONDUIT BUSHING

5975-00-665-0649 An item of metal and/or insulating material having internal threads designed to fit over the end of electrical conduit and/or fittings to provide a smooth interior with a rounded edge to prevent damage to the insulation of the wire or cable emerging therefrom. It may be designed to fit over the end of thin wall conduit, and to be fitted with holding (staking) screws, or it may be provided with internal straight threads for attaching to thick wall electrical conduit or fittings. It may be fitted with a temporary knockout cap (bushcap), and grounding or bonding facilities. For externally threaded items, see BOX CONNECTOR, ELECTRICAL; BUSHING, ELECTRICAL CONDUCTOR; CHASE NIPPLE, CONDUIT and BUSHING, STRAIN RELIEF, CABLE. See also FERRULE, ELECTRICAL CONDUIT. Excludes plain sleeve bushings.

Part Alternates: WF406, 5975-00-665-0649, 00-665-0649, 5975006650649, 006650649

Electrical and Electronic Equipment Components | Electrical Hardware and Supplies

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1963 00-665-0649

Drawings & Photos | NSN 5975-00-665-0649


Demand History | NSN 5975-00-665-0649

Part Number Request Date QTY Origin
WF406 2012-09-270 4 US

Cross Reference | NSN 5975-00-665-0649

Part Number Cage Code Manufacturer
WF406 81348 FEDERAL SPECIFICATIONS PROMULGATED BY GENERAL SERVICES

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5975-00-665-0649

Technical Data | NSN 5975-00-665-0649

Characteristic Specifications
STYLE DESIGNATOR A28 RIBBED
OVERALL LENGTH ANY ACCEPTABLE
ITEM ACCOMMODATED TRADE SIZE 3.000 INCHES SINGLE END
MATERIAL IRON
SURFACE TREATMENT CADMIUM
CONDUIT TYPE ACCOMMODATED RIGID METALLIC THICKWALL SINGLE END
NONDEFINITIVE SPEC/STD DATA B TYPE
MANUFACTURERS CODE 81348
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE WF406

Restrictions/Controls & Freight Information | NSN 5975-00-665-0649

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information