Product Details | SPECIAL PURPOSE ELECTRICAL INSULATION SLEEVING

5970-01-179-4542 A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.

Part Alternates: GS830P6033A, GS830P6-03-3A, 562A067-3-03/42, 562A06730342, 5970-01-179-4542, 01-179-4542, 5970011794542, 011794542

Electrical and Electronic Equipment Components | Electrical Insulators and Insulating Materials

Supply Group (FSG) NSN Assign. NIIN
59 18 MAY 1984 01-179-4542

Drawings & Photos | NSN 5970-01-179-4542


Cross Reference | NSN 5970-01-179-4542

Part Number Cage Code Manufacturer
562A067-3-03/42 06090 TYCO ELECTRONICS CORPORATION
GS830P6-03-3A 26512 NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NORTHROP GRUMMAN AEROSPACE

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5970-01-179-4542

Technical Data | NSN 5970-01-179-4542

Characteristic Specifications
STYLE DESIGNATOR B9 TRANSITION-1 TO 4 CABLES
MAIN BODY INSIDE DIAMETER 2.190 INCHES MINIMUM AS SUPPLIED 1.050 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER 1.060 INCHES MINIMUM AS SUPPLIED 0.510 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER 1.060 INCHES MINIMUM AS SUPPLIED 0.510 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH INSIDE DIAMETER 1.560 INCHES MINIMUM AS SUPPLIED 0.510 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FOURTH BRANCH INSIDE DIAMETER 1.060 INCHES MINIMUM AS SUPPLIED 0.510 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF SECOND BRANCH 4.000 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH 3.640 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
MAIN BODY WALL THICKNESS 0.180 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FIRST BRANCH WALL THICKNESS 0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
SECOND BRANCH WALL THICKNESS 0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
THIRD BRANCH WALL THICKNESS 0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
FOURTH BRANCH WALL THICKNESS 0.100 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
DISTANCE FROM EDGE OF MAIN BODY TO INTERSECTING CENTERLINES 4.270 INCHES NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG 10.0 NOMINAL AS SUPPLIED 45.0 NOMINAL AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG 10.0 NOMINAL AS SUPPLIED 15.0 NOMINAL AFTER UNRESTRICTED RECOVERY
MATERIAL PLASTIC, POLYOLEFIN, RT-301, RAYCHEM CORP
COLOR BLACK
FLEXIBILITY SEMIRIGID
TEMP RATING -55.0 DEG CELSIUS
MINIMUM TENSILE STRENGTH 1500 POUNDS PER SQUARE INCH
DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS 200.0 VOLTS PER MIL /0.001 INCH/
ENVIRONMENTAL PROTECTION CORROSION RESISTANT AND FLAME RESISTANT AND MILDEW RESISTANT AND SOLVENT RESISTANT AND WATER RESISTANT
RELIABILITY INDICATOR NOT ESTABLISHED
SPECIAL FEATURES INSIDE ADHESIVE COATED
MANUFACTURERS CODE 06090
DESIGN CONTROL REFERENCE 562A067-3-03/42

Restrictions/Controls & Freight Information | NSN 5970-01-179-4542

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 103300 INSULATING MATERIAL NOI
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code CX Defense Supply Center Richmond
Richmond, VA 23297-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5970-01-179-4542

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each