Product Details | NONCRYSTAL CONTROLLED OSCILLATOR

5963-00-631-5330 An oscillator whose operating frequency(ies) is controlled by an electronic device other than a CRYSTAL UNIT, QUARTZ. For an oscillator controlled by a crystal, see OSCILLATOR (1), CRYSTAL CONTROLLED. See also GENERATOR, SIGNAL; and CALIBRATOR, FREQUENCY. Excludes FREQUENCY SUPPLY, TELEPHONE CARRIER; RESONATOR, TUNING FORK; and OSCILLATOR, PULSE DELAY.20259550038Oscillators and Piezoelectric Crystals59630018Electronic Modules

Part Alternates: 7363036, 5963-00-631-5330, 00-631-5330, 5963006315330, 006315330

Electrical and Electronic Equipment Components | Electronic Modules

Supply Group (FSG) NSN Assign. NIIN
59 21 MAR 1975 00-631-5330

Drawings & Photos | NSN 5963-00-631-5330


Cross Reference | NSN 5963-00-631-5330

Part Number Cage Code Manufacturer
7363036 24930 EXELIS INC. DBA RADAR, RECONNAISSANCE & UNDERSEA

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5963-00-631-5330

Technical Data | NSN 5963-00-631-5330

Characteristic Specifications
FREQUENCY PER CHANNEL 58.5 KILOHERTZ MINIMUM OUTPUT CHANNEL AND 61.5 KILOHERTZ MAXIMUM OUTPUT CHANNEL
OVERALL GAIN 12.0 DECIBELS
IMPEDANCE RATING PER CHANNEL 75.000 OHMS OUTPUT CHANNEL
OPERATING TEMP RANGE -40.0 TO 70.0 DEG CELSIUS
BASIC SHAPE STYLE 1 RECTANGULAR OR SQUARE
OVERALL LENGTH 5.625 INCHES NOMINAL
OVERALL HEIGHT 1.656 INCHES NOMINAL
OVERALL WIDTH 2.470 INCHES NOMINAL
III END ITEM IDENTIFICATION 6625-00-174-7774 RADAR TEST SET
III FSC APPLICATION DATA ELECTRONIC MODULES

Restrictions/Controls & Freight Information | NSN 5963-00-631-5330

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating M 85
Less than truck load rating W Rating Variable
Water commodity Code 658 unknown
Originating Activity Code CL U.S. Army Communications-Electronics
Fort Monmouth, NJ 07703-5006
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5963-00-631-5330

Category Code Description
Materiel Category and Inventory ManagerQ Electronics Materiel (DLA/GSA Items)
Appropriation and Budget Activity2 Stock Fund Secondary Items
Management Inventory Segment2 NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable.
Specific Group/Generic Code0 Medical Materiel
Weapons Systems/End Item or Homogeneous Group00DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item
Accounting Requirements CodeX Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDADepartment of the Army
Service OrganizationAU.S. Army
ReparabilityZThis is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item.
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each