Product Details | DIGITAL MICROCIRCUIT

5962-01-574-0318 A microcircuit specifically designed to generate, modify, or process electrical signals which operate with two distinct or binary states. These states are commonly referred to as on and off, true and false, high and low, or "1" and "0".

Part Alternates: SN10KHT5541NT, 99007B7073, 5962-01-574-0318, 01-574-0318, 5962015740318, 015740318

Electrical and Electronic Equipment Components | Microcircuits, Electronic

Supply Group (FSG) NSN Assign. NIIN
59 13 MAY 2009 01-574-0318

Cross Reference | NSN 5962-01-574-0318

Part Number Cage Code Manufacturer
99007B7073 01365 MARINE CORPS LOGISTICS COMMAND TECHNICAL DATA REPOSITORY
SN10KHT5541NT 01295 TEXAS INSTRUMENTS INCORPORATED DBA TEXAS INSTRUMENTS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5962-01-574-0318

Technical Data | NSN 5962-01-574-0318

Characteristic Specifications
END ITEM IDENTIFICATION 6625-01-513-6372, AN/PSM-105 PROGRAM SET
OVERALL WIDTH 0.300 INCHES NOMINAL
OVERALL LENGTH 1.245 INCHES NOMINAL
OVERALL HEIGHT 0.325 INCHES NOMINAL
SPECIAL FEATURES SUPPLY VOLTAGE VCC -0.5 V TO 7 V;SUPPLY VOLTAGE VEE -8 V TO 0 V;INPUT VOLTAGE TTL -1.2 V TO 7 V;INPUT CURRENT TTL -30 MA TO 5 MA;OPER TEMP 0 DEG C TO 75 DEG C;STORAGE TEMP -65 DEG C TO 150 DEG C
PART NAME ASSIGNED BY CONTROLLING AGENCY MICROCIRCUIT, DIITAL - ECL TO TTL TRANSLATOR
TERMINAL TYPE AND QUANTITY 24 PIN

Restrictions/Controls & Freight Information | NSN 5962-01-574-0318

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:BESD sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating P 77.5
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code PA Marine Corps Logistics Base
Albany, GA 31704-1128
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 5962-01-574-0318

Category Code Description
Stores Account Code1Marine Corps Stock Fund Account Item.
Combat Essentiality Code6Critical Repair Part to a Non-Combat Essential End Item. Those parts or components whose failure in a noncombat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency.
Materiel Management CodeBAll CommoditiesDefense Logistics Agency, (DLA,)
Echelon Management Code2ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDMU.S. Marine Corps
Service OrganizationMU.S. Marine Corps
ReparabilityZNonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code.
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each