NSN 5962-01-362-3533 CD54HCT123F/3A, CD54HCT123F3A, 5962-89700
Product Details | DIGITAL MICROCIRCUIT
5962-01-362-3533 A microcircuit specifically designed to generate, modify, or process electrical signals which operate with two distinct or binary states. These states are commonly referred to as on and off, true and false, high and low, or "1" and "0".
Part Alternates: CD54HCT123F/3A, CD54HCT123F3A, 5962-89700, 59628970001EA, 5962-8970001EA, 59628970001EB, 5962-8970001EB, 59628970001EX, 5962-8970001EX, 74HCT123D, 5962-01-362-3533, 01-362-3533, 5962013623533, 596289700, 013623533
Electrical and Electronic Equipment Components | Microcircuits, Electronic
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 05 AUG 1992 | 01-362-3533 | 31779 ( MICROCIRCUIT, DIGITAL ) |
Demand History | NSN 5962-01-362-3533
Part Number | Request Date | QTY | Origin |
---|---|---|---|
5962-01-362-3533 | 2021-05-148 | 20 | DIBBS |
5962-01-362-3533 | 2021-05-137 | 20 | DIBBS |
5962-01-362-3533 | 2018-12-341 | 50 | DIBBS |
5962-01-362-3533 | 2018-11-330 | 50 | DIBBS |
5962-01-362-3533 | 2012-01-25 | 24 | DIBBS |
Cross Reference | NSN 5962-01-362-3533
Part Number | Cage Code | Manufacturer |
---|---|---|
5962-89700 | 67268 | DLA LAND AND MARITIME OPNS SUPPORT GROUP |
5962-8970001EA | 67268 | DLA LAND AND MARITIME OPNS SUPPORT GROUP |
5962-8970001EB | 67268 | DLA LAND AND MARITIME OPNS SUPPORT GROUP |
5962-8970001EX | 67268 | DLA LAND AND MARITIME OPNS SUPPORT GROUP |
74HCT123D | 18324 | PHILIPS SEMICONDUCTORS INC |
CD54HCT123F/3A | 01295 | TEXAS INSTRUMENTS INCORPORATED DBA TEXAS INSTRUMENTS |
CD54HCT123F/3A | 34371 | INTERSIL CORPORATION |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5962-01-362-3533
Related Products | NSN 5962-01-362-3533
Technical Data | NSN 5962-01-362-3533
Characteristic | Specifications |
---|---|
OUTPUT LOGIC FORM | COMPLEMENTARY-METAL OXIDE-SEMICONDUCTOR LOGIC |
DESIGN FUNCTION AND QUANTITY | 2 MULTIVIBRATOR, MONOSTABLE |
INPUT CIRCUIT PATTERN | DUAL 3 INPUT |
VOLTAGE RATING AND TYPE PER CHARACTERISTIC | -0.5 VOLTS MAXIMUM NEGATIVE POWER SUPPLY SPAN AND 7.0 VOLTS MAXIMUM POSITIVE POWER SUPPLY SPAN |
CURRENT RATING PER CHARACTERISTIC | -25.00 MILLIAMPERES MAXIMUM DRAIN/SOURCE ON RESISTIVE AND 25.00 MILLIAMPERES MAXIMUM DRAIN/SOURCE ON RESISTIVE |
OPERATING TEMP RANGE | -55.0 TO 125.0 DEG CELSIUS |
TERMINAL TYPE AND QUANTITY | 16 PRINTED CIRCUIT |
TERMINAL SURFACE TREATMENT | SOLDER |
INCLOSURE CONFIGURATION | DUAL-IN-LINE |
INCLOSURE MATERIAL | CERAMIC |
CASE OUTLINE SOURCE AND DESIGNATOR | D-2 MIL-M-38510 |
BODY LENGTH | 0.840 INCHES MAXIMUM |
BODY HEIGHT | 0.200 INCHES MAXIMUM |
BODY WIDTH | 0.310 INCHES MAXIMUM |
MAXIMUM POWER DISSIPATION RATING | 500.0 MILLIWATTS |
STORAGE TEMP RANGE | -65.0 TO 150.0 DEG CELSIUS |
FEATURES PROVIDED | HIGH SPEED AND RETRIGGERABLE AND W/RESET |
TEST DATA DOCUMENT | 96909-MIL-STD-883 STANDARD |
MANUFACTURERS CODE | 67268 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | 5962-89700 |
MANUFACTURERS CODE | 67268 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | 5962-8970001EA |
Restrictions/Controls & Freight Information | NSN 5962-01-362-3533
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | Q | Strategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.” |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Electro-static Discharge Susceptible: | B | ESD sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | P | 77.5 |
Less than truck load rating | W | Rating Variable |
Water commodity Code | 72D | unknown |
Originating Activity Code | TH | Defense Supply Center Columbus Columbus, OH 43215 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | 3 | Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices). |
Management | NSN 5962-01-362-3533
Category | Code | Description |
---|---|---|
Budget Code | 9 | General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors. |
Materiel Management Aggregation Code | EH | SX:ELECTRONIC COMPONENTS |
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DF | Department of the Air Force |
Service Organization | F | U.S. Air Force |
Reparability | N | Stock Fund (except Munitions) |
Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |