NSN 5962-01-262-9863 CDP1857/CD/3W, CDP1857CD3W, HB18570D000
Product Details | DIGITAL MICROCIRCUIT
5962-01-262-9863 A microcircuit specifically designed to generate, modify, or process electrical signals which operate with two distinct or binary states. These states are commonly referred to as on and off, true and false, high and low, or "1" and "0".
Part Alternates: CDP1857/CD/3W, CDP1857CD3W, HB18570D000, HB1857-0-D-000, SMB939524140, SM-B-939524-140, 5962-01-262-9863, 01-262-9863, 5962012629863, 012629863
Electrical and Electronic Equipment Components | Microcircuits, Electronic
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 07 SEP 1987 | 01-262-9863 | 31779 ( MICROCIRCUIT, DIGITAL ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5962-01-262-9863
Related Products | NSN 5962-01-262-9863
Technical Data | NSN 5962-01-262-9863
Characteristic | Specifications |
---|---|
OUTPUT LOGIC FORM | COMPLEMENTARY-METAL OXIDE-SEMICONDUCTOR LOGIC |
DESIGN FUNCTION AND QUANTITY | 4 SEPARATOR AND 4 BUFFER |
INPUT CIRCUIT PATTERN | QUAD 2 INPUT |
VOLTAGE RATING AND TYPE PER CHARACTERISTIC | 7.0 VOLTS MAXIMUM POWER SOURCE |
OPERATING TEMP RANGE | -55.0 TO 125.0 DEG CELSIUS |
TERMINAL TYPE AND QUANTITY | 16 PRINTED CIRCUIT |
TERMINAL SURFACE TREATMENT | SOLDER |
INCLOSURE CONFIGURATION | DUAL-IN-LINE |
INCLOSURE MATERIAL | CERAMIC |
BODY LENGTH | 0.785 INCHES MAXIMUM |
BODY HEIGHT | 0.160 INCHES MAXIMUM |
BODY WIDTH | 0.260 INCHES MAXIMUM |
MAXIMUM POWER DISSIPATION RATING | 500.0 MILLIWATTS |
STORAGE TEMP RANGE | -65.0 TO 150.0 DEG CELSIUS |
FEATURES PROVIDED | MONOLITHIC |
TEST DATA DOCUMENT | 02735-CDP1857/CD/3W DRAWING |
Restrictions/Controls & Freight Information | NSN 5962-01-262-9863
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | Q | Strategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.” |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Electro-static Discharge Susceptible: | B | ESD sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | P | 77.5 |
Less than truck load rating | W | Rating Variable |
Water commodity Code | 72D | unknown |
Originating Activity Code | TH | Defense Supply Center Columbus Columbus, OH 43215 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | 3 | Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices). |
Management | NSN 5962-01-262-9863
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | Q | Electronics Materiel (DLA/GSA Items) |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 00 | DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |