NSN 5962-00-001-8577 MC813G , MC913G, SC3272G
Product Details | DIGITAL MICROCIRCUIT
5962-00-001-8577 A microcircuit specifically designed to generate, modify, or process electrical signals which operate with two distinct or binary states. These states are commonly referred to as on and off, true and false, high and low, or "1" and "0".
Part Alternates: MC813G , MC913G, SC3272G, SC6686GH1, SL2119, HL71929, DMS84007, 71482643, 7148-264-3 , 913HC , 913HMQB, 1134R, 221G3032, 3517026060, 351-7026-060, 3517206130, 351-7206-130, 3517206132, 351-7206-132, 5962-00-001-8577, 00-001-8577, 5962000018577, 000018577
Electrical and Electronic Equipment Components | Microcircuits, Electronic
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 04 OCT 1972 | 00-001-8577 | 31779 ( MICROCIRCUIT, DIGITAL ) |
Cross Reference | NSN 5962-00-001-8577
Part Number | Cage Code | Manufacturer |
---|---|---|
1134R | 15124 | PHILCO-FORD CORP MICROELECTRONICS DIV |
221G3032 | 67177 | ZENITH ELECTRONICS CORPORATION |
351-7026-060 | 13499 | ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS |
351-7206-130 | 13499 | ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS |
351-7206-132 | 13499 | ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS |
7148-264-3 | 80294 | BOURNS INSTRUMENTS INC |
913HC | 07263 | FAIRCHILD SEMICONDUCTOR CORP |
913HMQB | 07263 | FAIRCHILD SEMICONDUCTOR CORP |
DMS84007 | 16236 | DLA LAND AND MARITIME |
HL71929 | 07263 | FAIRCHILD SEMICONDUCTOR CORP |
MC813G | 04713 | FREESCALE SEMICONDUCTOR, INC. |
MC913G | 04713 | FREESCALE SEMICONDUCTOR, INC. |
SC3272G | 04713 | FREESCALE SEMICONDUCTOR, INC. |
SC6686GH1 | 04713 | FREESCALE SEMICONDUCTOR, INC. |
SL2119 | 07263 | FAIRCHILD SEMICONDUCTOR CORP |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5962-00-001-8577
Related Products | NSN 5962-00-001-8577
Technical Data | NSN 5962-00-001-8577
Characteristic | Specifications |
---|---|
OUTPUT LOGIC FORM | RESISTOR-TRANSISTOR LOGIC |
DESIGN FUNCTION AND QUANTITY | 1 FLIP-FLOP, CLOCKED AND 1 FLIP-FLOP, D-TYPE |
INPUT CIRCUIT PATTERN | 4 INPUT |
VOLTAGE RATING AND TYPE PER CHARACTERISTIC | 4.0 VOLTS MAXIMUM POWER SOURCE |
OPERATING TEMP RANGE | -55.0 TO 125.0 DEG CELSIUS |
TERMINAL TYPE AND QUANTITY | 8 PIN |
TERMINAL SURFACE TREATMENT | GOLD |
INCLOSURE CONFIGURATION | CAN |
INCLOSURE MATERIAL | GLASS AND METAL |
CASE OUTLINE SOURCE AND DESIGNATOR | T0-99 JOINT ELECTRON DEVICE ENGINEERING COUNCIL |
BODY OUTSIDE DIAMETER | 0.335 INCHES MINIMUM AND 0.370 INCHES MAXIMUM |
BODY HEIGHT | 0.165 INCHES MINIMUM AND 0.185 INCHES MAXIMUM |
MAXIMUM POWER DISSIPATION RATING | 250.0 MILLIWATTS |
STORAGE TEMP RANGE | -65.0 TO 150.0 DEG CELSIUS |
FEATURES PROVIDED | HERMETICALLY SEALED AND MONOLITHIC AND NEGATIVE OUTPUTS AND POSITIVE OUTPUTS AND MEDIUM POWER AND MEDIUM SPEED AND W/CLEAR AND EDGE TRIGGERED |
TEST DATA DOCUMENT | 13499-351-7206 DRAWING |
III UNPACKAGED UNIT WEIGHT | 1.2 GRAMS |
III PRECIOUS MATERIAL | GOLD |
III PRECIOUS MATERIAL AND LOCATION | TERMINALS GOLD |
Restrictions/Controls & Freight Information | NSN 5962-00-001-8577
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | Q | Strategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.” |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Electro-static Discharge Susceptible: | B | ESD sensitivity |
Precious Metals Indicator Code: | G | Item contains gold |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | P | 77.5 |
Less than truck load rating | W | Rating Variable |
Water commodity Code | 72D | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | 3 | Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices). |
Management | NSN 5962-00-001-8577
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | Q | Electronics Materiel (DLA/GSA Items) |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 00 | DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | A | Item requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. Refer to appropriate manuals or directives for specific instructions. |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Budget Code | 9 | General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors. |
Materiel Management Aggregation Code | EH | SX:ELECTRONIC COMPONENTS |
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DF | Department of the Air Force |
Service Organization | F | U.S. Air Force |
Reparability | N | Stock Fund (except Munitions) |
Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |