NSN 5961-01-539-1977 1N3903, 01-539-1977, 015391977
Product Details | SEMICONDUCTOR DEVICE RECTIFIER
5961-01-539-1977 Two or more interconnected SEMICONDUCTOR DEVICE (1), DIODE arranged in stack(s) for use in power supplies to change alternating current to direct current. For items containing material such as selenium or copper oxide, see RECTIFIER, METALLIC.
Part Alternates: 1N3903, 5961-01-539-1977, 01-539-1977, 5961015391977, 015391977
Electrical and Electronic Equipment Components | Semiconductor Devices and Associated Hardware
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 13 APR 2006 | 01-539-1977 | 00300 ( RECTIFIER, SEMICONDUCTOR DEVICE ) |
Demand History | NSN 5961-01-539-1977
Part Number | Request Date | QTY | Origin |
---|---|---|---|
1N3903 | 2021-03-75 | 2 | DIBBS |
1N3903 | 2020-08-223 | 1 | DIBBS |
1N3903 | 2020-07-210 | 1 | DIBBS |
1N3903 | 2020-05-139 | 1 | DIBBS |
1N3903 | 2020-05-128 | 1 | DIBBS |
1N3903 | 2019-09-247 | 1 | DIBBS |
Cross Reference | NSN 5961-01-539-1977
Part Number | Cage Code | Manufacturer |
---|---|---|
1N3903 | 14936 | GENERAL SEMICONDUCTOR INC |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5961-01-539-1977
Related Products | NSN 5961-01-539-1977
Technical Data | NSN 5961-01-539-1977
Characteristic | Specifications |
---|---|
ABSOLUTE MAXIMUM VOLTAGE RATING IN VOLTS PER CHARACTERISTIC | 20.0 FORWARD VOLTAGE, AVERAGE |
ABSOLUTE MAXIMUM CURRENT RATING PER CHARACTERISTIC | 6.00 MICROAMPERES REVERSE CURRENT, PEAK |
MOUNTING METHOD | THREADED STUD |
TERMINAL TYPE AND QUANTITY | 1 THREADED STUD |
OPERATING TEMP RANGE | -65.0 TO 150.0 DEG CELSIUS |
OVERALL LENGTH | 1.172 INCHES MINIMUM AND 1.453 INCHES MAXIMUM |
OVERALL DIAMETER | 0.669 INCHES MINIMUM AND 0.688 INCHES MAXIMUM |
SPECIAL FEATURES | STANDARD POLARITY: STUD IS CATHODE; 1/4-28 UNF 3A THREADS |
III END ITEM IDENTIFICATION | NSN 2350-01-506-0132; ARMORED RECONNAISSANCE-ARIBORNE ASSUALT VEHICLE |
Restrictions/Controls & Freight Information | NSN 5961-01-539-1977
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 063025 | SEMICONDUCTORS/DEVICES NOI ETC |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 72D | unknown |
Originating Activity Code | AZ | U.S. Army Tank-Automotive and Armaments Command Warren, MI 48397-5000 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5961-01-539-1977
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | Q | Electronics Materiel (DLA/GSA Items) |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 00 | DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |