Product Details | TRANSISTOR

5961-01-226-3731 An active semiconductor device with three or more electrodes. May or may not include mounting hardware and/or heatsink. Excludes SEMICONDUCTOR DEVICE, DIODE and SEMICONDUCTOR DEVICE, THYRISTOR. For solid state devices which are responsive to visible or infrared radiant energy, see SEMICONDUCTOR DEVICE, PHOTO.

Part Alternates: 2004104814, 2SA10480, 2SA1048-0, 5961-01-226-3731, 01-226-3731, 5961012263731, 012263731

Electrical and Electronic Equipment Components | Semiconductor Devices and Associated Hardware

Supply Group (FSG) NSN Assign. NIIN
59 15 FEB 1986 01-226-3731

Cross Reference | NSN 5961-01-226-3731

Part Number Cage Code Manufacturer
2004104814 56614 VIDEOTEK INC.
2SA1048-0 56614 VIDEOTEK INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5961-01-226-3731

Technical Data | NSN 5961-01-226-3731

Characteristic Specifications
SEMICONDUCTOR MATERIAL SILICON
INTERNAL CONFIGURATION JUNCTION CONTACT
VOLTAGE RATING IN VOLTS PER CHARACTERISTIC -50.0 MAXIMUM BREAKDOWN VOLTAGE, COLLECTOR-TO-BASE, EMITTER OPEN AND -50.0 MAXIMUM BREAKDOWN VOLTAGE, COLLECTOR-TO-EMITTER, BASE OPEN AND -5.0 MAXIMUM BREAKDOWN VOLTAGE, EMITTER-TO-BASE, COLLECTOR OPEN
CURRENT RATING PER CHARACTERISTIC 150.00 MILLIAMPERES MAXIMUM COLLECTOR CURRENT, DC
POWER RATING PER CHARACTERISTIC 200.0 MILLIWATTS MAXIMUM COLLECTOR POWER DISSIPATION
TRANSFER RATIO 70.0 MINIMUM STATIC FORWARD CURRENT TRANSFER RATIO, COMMON-EMITTER
MAXIMUM OPERATING TEMP PER MEASUREMENT POINT 125.0 DEG CELSIUS JUNCTION
INCLOSURE MATERIAL METAL
MOUNTING METHOD TERMINAL
TERMINAL LENGTH 0.539 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY 3 UNINSULATED WIRE LEAD
OVERALL LENGTH 0.126 INCHES MAXIMUM
OVERALL HEIGHT 0.094 INCHES MAXIMUM
OVERALL WIDTH 0.165 INCHES MAXIMUM
FEATURES PROVIDED HERMETICALLY SEALED CASE
SPECIAL FEATURES JUNCTION PATTERN ARRANGEMENT: PNP

Restrictions/Controls & Freight Information | NSN 5961-01-226-3731

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063025 SEMICONDUCTORS/DEVICES NOI ETC
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5961-01-226-3731

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each