Product Details | THYRISTOR SEMICONDUCTOR DEVICE

5961-01-211-5180 A bistable semiconductor device comprising three or more junctions which is normally a nonconductor until the application of a signal to a gate terminal, at which time the device switches to the conductive state. Includes devices capable of being switched back to the nonconductive state upon application of a different signal to the same or another gate terminal. May or may not include mounting hardware and/or heatsink. For solid state devices which are responsive to visible or infrared radiant energy, see SEMICONDUCTOR DEVICE, PHOTO.

Part Alternates: D217973, D21797-3, C46P, 5961-01-211-5180, 01-211-5180, 5961012115180, 012115180

Electrical and Electronic Equipment Components | Semiconductor Devices and Associated Hardware

Supply Group (FSG) NSN Assign. NIIN
59 27 JUN 1985 01-211-5180

Cross Reference | NSN 5961-01-211-5180

Part Number Cage Code Manufacturer
C46P 03508 GENERAL ELECTRIC CO SEMI-CONDUCTOR PRODUCTS DEPT
D21797-3 07860 BOGUE ELECTRIC MANUFACTURING CO

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5961-01-211-5180

Technical Data | NSN 5961-01-211-5180

Characteristic Specifications
SEMICONDUCTOR MATERIAL SILICON
INTERNAL CONFIGURATION JUNCTION CONTACT
VOLTAGE RATING IN VOLTS PER CHARACTERISTIC 1000.0 MAXIMUM REPETITIVE PEAK OFF-STATE VOLTAGE AND 1000.0 MAXIMUM REPETITIVE PEAK REVERSE VOLTAGE AND 1200.0 MAXIMUM NONREPETITIVE PEAK REVERSE VOLTAGE
CURRENT RATING PER CHARACTERISTIC 80.00 AMPERES MAXIMUM ON-STATE CURRENT, RMS TOTAL AND 800.00 AMPERES MAXIMUM PEAK ON-STATE CURRENT, NONREPETITIVE
POWER RATING PER CHARACTERISTIC 2.0 WATTS MAXIMUM AVERAGE GATE POWER DISSIPATION
MAXIMUM OPERATING TEMP PER MEASUREMENT POINT 125.0 DEG CELSIUS JUNCTION
INCLOSURE MATERIAL METAL
MOUNTING METHOD THREADED STUD
MOUNTING FACILITY QUANTITY 1
THREAD SERIES DESIGNATOR UNF
NOMINAL THREAD SIZE 0.500 INCHES
TERMINAL TYPE AND QUANTITY 3 TAB, SOLDER LUG
OVERALL LENGTH 2.577 INCHES MAXIMUM
OVERALL WIDTH ACROSS FLATS 1.062 INCHES MAXIMUM
FEATURES PROVIDED HERMETICALLY SEALED CASE
SPECIAL FEATURES JUNCTION PATTERN ARRANGEMENT: PNPN
(NON-CORE DATA) UNPACKAGED UNIT WEIGHT 2.750 OUNCES

Restrictions/Controls & Freight Information | NSN 5961-01-211-5180

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063025 SEMICONDUCTORS/DEVICES NOI ETC
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5961-01-211-5180

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each