NSN 5961-01-105-3650 SD213DE, SD213EE, SDF9213
Product Details | TRANSISTOR
5961-01-105-3650 An active semiconductor device with three or more electrodes. May or may not include mounting hardware and/or heatsink. Excludes SEMICONDUCTOR DEVICE, DIODE and SEMICONDUCTOR DEVICE, THYRISTOR. For solid state devices which are responsive to visible or infrared radiant energy, see SEMICONDUCTOR DEVICE, PHOTO.
Part Alternates: SD213DE, SD213EE, SDF9213, DM1106, 4014444-04, 477729, 842SO213, 842-SO2-13, 5961-01-105-3650, 01-105-3650, 5961011053650, 401444404, 011053650
Electrical and Electronic Equipment Components | Semiconductor Devices and Associated Hardware
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 20 DEC 1980 | 01-105-3650 | 20588 ( TRANSISTOR ) |
Cross Reference | NSN 5961-01-105-3650
Part Number | Cage Code | Manufacturer |
---|---|---|
4014444-04 | 1PQF4 | L-3 COMMUNICATIONS CORPORATION DBA LINK SIMULATION & TRAINING |
4014444-04 | 36378 | RAYTHEON TECHNICAL SERVICES COMPANY |
477729 | 89536 | FLUKE CORPORATION |
842-SO2-13 | 25965 | AMETEK PROGRAMMABLE POWER, INC. DBA AMTEK NORTH |
DM1106 | 17856 | SILICONIX INCORPORATED DIV SILICONIX |
SD213DE | 0ANF0 | TOPAZ SEMICONDUCTOR INC SUB OF HYTEK MICROSYSTEMS INC |
SD213DE | 17856 | SILICONIX INCORPORATED DIV SILICONIX |
SD213DE | 18324 | PHILIPS SEMICONDUCTORS INC |
SD213EE | 18324 | PHILIPS SEMICONDUCTORS INC |
SDF9213 | 21845 | SOLITRON DEVICES, INC. |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5961-01-105-3650
Related Products | NSN 5961-01-105-3650
Technical Data | NSN 5961-01-105-3650
Characteristic | Specifications |
---|---|
SEMICONDUCTOR MATERIAL | SILICON |
INTERNAL CONFIGURATION | FIELD EFFECT |
(NON-CORE DATA) CHANNEL POLARITY AND CONTROL TYPE | N-CHANNEL JUNCTION TYPE |
VOLTAGE RATING IN VOLTS PER CHARACTERISTIC | 30.0 MAXIMUM DRAIN TO SOURCE VOLTAGE AND 40.0 MAXIMUM GATE TO SOURCE VOLTAGE |
CURRENT RATING PER CHARACTERISTIC | 50.00 MILLIAMPERES MAXIMUM DRAIN CURRENT |
POWER RATING PER CHARACTERISTIC | 1.2 WATTS MAXIMUM TOTAL POWER DISSIPATION |
MAXIMUM OPERATING TEMP PER MEASUREMENT POINT | 125.0 DEG CELSIUS AMBIENT AIR |
INCLOSURE MATERIAL | METAL |
JOINT ELECTRONIC DEVICE ENGINEERING COUNCIL/JEDEC/CASE OUTLINE DESIGNATION | TO-72 |
MOUNTING METHOD | TERMINAL |
TERMINAL LENGTH | 0.500 INCHES MINIMUM |
TERMINAL CIRCLE DIAMETER | 0.100 INCHES NOMINAL |
TERMINAL TYPE AND QUANTITY | 4 UNINSULATED WIRE LEAD |
OVERALL LENGTH | 0.170 INCHES MINIMUM AND 0.210 INCHES MAXIMUM |
OVERALL DIAMETER | 0.209 INCHES MINIMUM AND 0.230 INCHES MAXIMUM |
FEATURES PROVIDED | HERMETICALLY SEALED CASE |
Restrictions/Controls & Freight Information | NSN 5961-01-105-3650
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Electro-static Discharge Susceptible: | B | ESD sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 063025 | SEMICONDUCTORS/DEVICES NOI ETC |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 72D | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | 3 | Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices). |
Management | NSN 5961-01-105-3650
Category | Code | Description |
---|---|---|
Budget Code | 9 | General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors. |
Materiel Management Aggregation Code | EH | SX:ELECTRONIC COMPONENTS |
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DF | Department of the Air Force |
Service Organization | F | U.S. Air Force |
Reparability | N | Stock Fund (except Munitions) |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |