Product Details | TRANSISTOR

5961-01-063-5461 An active semiconductor device with three or more electrodes. May or may not include mounting hardware and/or heatsink. Excludes SEMICONDUCTOR DEVICE, DIODE and SEMICONDUCTOR DEVICE, THYRISTOR. For solid state devices which are responsive to visible or infrared radiant energy, see SEMICONDUCTOR DEVICE, PHOTO.

Part Alternates: 0N2280272, 0N228027-2, 5961-01-063-5461, 01-063-5461, 5961010635461, 010635461

Electrical and Electronic Equipment Components | Semiconductor Devices and Associated Hardware

Supply Group (FSG) NSN Assign. NIIN
59 08 AUG 1978 01-063-5461

Cross Reference | NSN 5961-01-063-5461

Part Number Cage Code Manufacturer
0N228027-2 98230 NATIONAL SECURITY AGENCY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5961-01-063-5461

Technical Data | NSN 5961-01-063-5461

Characteristic Specifications
SEMICONDUCTOR MATERIAL SILICON
VOLTAGE RATING IN VOLTS PER CHARACTERISTIC 150.0 MAXIMUM COLLECTOR TO EMITTER VOLTAGE/STATIC/BASE OPEN
CURRENT RATING PER CHARACTERISTIC 25.00 AMPERES MAXIMUM COLLECTOR CURRENT, DC
POWER RATING PER CHARACTERISTIC 200.0 WATTS MAXIMUM TOTAL DEVICE DISSIPATION
MAXIMUM OPERATING TEMP PER MEASUREMENT POINT 200.0 DEG CELSIUS AMBIENT AIR
INCLOSURE MATERIAL METAL
MOUNTING METHOD TERMINAL
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
OVERALL LENGTH 1.550 INCHES NOMINAL
OVERALL HEIGHT 0.345 INCHES NOMINAL
OVERALL WIDTH 1.050 INCHES NOMINAL
FEATURES PROVIDED HERMETICALLY SEALED CASE
SPECIAL FEATURES JUNCTION PATTERN ARRANGEMENT: NPN
TEST DATA DOCUMENT 98230-0N228027-2 DRAWING
MANUFACTURERS CODE 98230
DESIGN CONTROL REFERENCE 0N228027-2

Restrictions/Controls & Freight Information | NSN 5961-01-063-5461

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:BESD sensitivity
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063025 SEMICONDUCTORS/DEVICES NOI ETC
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code XP National Security Agency
Fort George G. Meade, MD 20755-6000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 5961-01-063-5461

Category Code Description
Materiel Management Aggregation CodeCSSJ:COMMUNICATIONS SECURITY (COMSEC) OTHER THAN SERIALIZED CONTROL ITEM
Budget CodeK 8357X3080:Cryptologic and Other USAF Security Service Equipment
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeROMajor repair.
Source of SupplyFPDAir Force Cryptologic Support Center (ESC)
San Antonio, TX 78243-5000
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesMRESTRICTED REQUISITIONS-MAJOR OVERHAUL (Service/Agency use only.) # Items (Assemblies and/or component parts) which for lack of specialized tools, test equipment, etc., can be used only by major overhaul activities. Base, post, camp or station activities will not requisition unless authorized to perform major overhaul function.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each