NSN 5961-01-011-5192 6550821, 655-082-1, 6650821
Product Details | UNITIZED SEMICONDUCTOR DEVICE RECTIFIER
5961-01-011-5192 Two or more diode semiconductor devices designed to function as a unit in changing alternating current to direct current. The diode devices are internally connected in series, and are permanently cased, encapsulated, potted, or molded together to form an inseparable unit. These units may be designed as either half-wave or full-wave rectifiers and may be mounted to form either single phase or three phase bridges. For interconnected items arranged in stack(s), see RECTIFIER, SEMICONDUCTOR DEVICE. For items fabricated in the form of a monolithic or thin film structure that perform the function of a circuit, see INTEGRATED CIRCUIT (as modified). Excludes SEMICONDUCTOR DEVICES, UNITIZED; SEMICONDUCTOR DEVICE ASSEMBLY; and RECTIFIER NETWORK, UNITIZED.
Part Alternates: 6550821, 655-082-1, 6650821, 665-082-1, 7903528-00, 5961-01-011-5192, 01-011-5192, 5961010115192, 010115192, 790352800
Electrical and Electronic Equipment Components | Semiconductor Devices and Associated Hardware
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 23 OCT 1975 | 01-011-5192 | 62108 ( RECTIFIER, SEMICONDUCTOR DEVICE, UNITIZED ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5961-01-011-5192
Technical Data | NSN 5961-01-011-5192
Characteristic | Specifications |
---|---|
SPECIAL FEATURES | CENTER TAP RECTIFIER;PEAK INVERSE VOLTAGE 100V;FORWARD CURRENT SURGE 15O AMP;OUTPUT CURRENT 15 AMP MAX;OPERATING TEMP M65 TO P150 DEG C;GLASS DIODES;EPOXY ENCAPSULATED WITH ALUMINUM FRAME;3 WIRE LOOP TYPE TERMINALS;2.260 IN. MAX LG;0.354 IN. MAX W;0.322 IN. MAX H;TWO 0.175 IN. MAX DIA MTG HOLES 1.880 IN. CENTER TO CENTER;POSITIVE POLARITY;STORAGE TEMP RANGE:M65.0 TO P150.0 DEG CELCIUS |
Restrictions/Controls & Freight Information | NSN 5961-01-011-5192
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 063025 | SEMICONDUCTORS/DEVICES NOI ETC |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 72D | unknown |
Originating Activity Code | ZA | Australia ZB ZC |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5961-01-011-5192
Category | Code | Description |
---|---|---|
Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
Combat Essentiality Code | 2 | Non-Critical Repair Part. Repair parts or major components whose failure in an end item will not render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency, and which do not fit the definition of Code 3 or 4 items. |
Materiel Management Code | E | Electronics MaterielDefense Electronics Supply Center (DESC) |
Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
Physical Category Code | 1 | Bin |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DM | U.S. Marine Corps |
Service Organization | M | U.S. Marine Corps |
Reparability | Z | Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code. |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |