NSN 5961-00-137-2340 SMA6968691, SM-A-696869-1, 2N2857
Product Details | TRANSISTOR
5961-00-137-2340 An active semiconductor device with three or more electrodes. May or may not include mounting hardware and/or heatsink. Excludes SEMICONDUCTOR DEVICE, DIODE and SEMICONDUCTOR DEVICE, THYRISTOR. For solid state devices which are responsive to visible or infrared radiant energy, see SEMICONDUCTOR DEVICE, PHOTO.
Part Alternates: SMA6968691, SM-A-696869-1, 2N2857, 332800000001, 332-800000-001, 332800004001, 332-800004-001, 5961-00-137-2340, 00-137-2340, 5961001372340, 001372340
Electrical and Electronic Equipment Components | Semiconductor Devices and Associated Hardware
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 28 JUL 1971 | 00-137-2340 | 20588 ( TRANSISTOR ) |
Cross Reference | NSN 5961-00-137-2340
Part Number | Cage Code | Manufacturer |
---|---|---|
2N2857 | 04713 | FREESCALE SEMICONDUCTOR, INC. |
2N2857 | 15818 | TELCOM SEMICONDUCTOR INC |
2N2857 | 1MY79 | INTERSIL COMMUNICATIONS INC. |
2N2857 | 27014 | NATIONAL SEMICONDUCTOR CORPORATION |
2N2857 | 34371 | INTERSIL CORPORATION |
332-800000-001 | 90073 | CMC ELECTRONICS INC |
332-800004-001 | 90073 | CMC ELECTRONICS INC |
SM-A-696869-1 | 80063 | US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5961-00-137-2340
Related Products | NSN 5961-00-137-2340
Technical Data | NSN 5961-00-137-2340
Characteristic | Specifications |
---|---|
SEMICONDUCTOR MATERIAL | SILICON |
INTERNAL CONFIGURATION | JUNCTION CONTACT |
VOLTAGE RATING IN VOLTS PER CHARACTERISTIC | 30.0 MAXIMUM COLLECTOR TO BASE VOLTAGE/STATIC/EMITTER OPEN AND 15.0 MAXIMUM COLLECTOR TO EMITTER VOLTAGE/STATIC/BASE OPEN AND 3.0 MAXIMUM EMITTER TO BASE VOLTAGE, STATIC, COLLECTOR OPEN |
CURRENT RATING PER CHARACTERISTIC | 40.00 MILLIAMPERES MAXIMUM COLLECTOR CURRENT, DC |
POWER RATING PER CHARACTERISTIC | 300.0 MILLIWATTS MAXIMUM TOTAL POWER DISSIPATION |
MAXIMUM OPERATING TEMP PER MEASUREMENT POINT | 200.0 DEG CELSIUS JUNCTION |
INCLOSURE MATERIAL | METAL |
MOUNTING METHOD | TERMINAL |
TERMINAL LENGTH | 0.500 INCHES MINIMUM |
TERMINAL TYPE AND QUANTITY | 4 UNINSULATED WIRE LEAD |
OVERALL LENGTH | 0.210 INCHES MAXIMUM |
OVERALL DIAMETER | 0.230 INCHES NOMINAL |
SPECIAL FEATURES | JUNCTION PATTERN ARRANGEMENT: NPN |
TEST DATA DOCUMENT | 80063-SM-A-696869 DRAWING |
(NON-CORE DATA) SPECIFICATION/STANDARD DATA | 81349-MIL-S-19500/343 GOVERNMENT SPECIFICATION |
Restrictions/Controls & Freight Information | NSN 5961-00-137-2340
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Electro-static Discharge Susceptible: | B | ESD sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 063025 | SEMICONDUCTORS/DEVICES NOI ETC |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 658 | unknown |
Originating Activity Code | CL | U.S. Army Communications-Electronics Fort Monmouth, NJ 07703-5006 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5961-00-137-2340
Category | Code | Description |
---|---|---|
Cognizance Codes | 9N | Navy-owned stocks of defense electronic material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | S9E | Defense Supply Center Columbus Columbus, OH 43218 |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |