NSN 5961-00-103-7413 12991166, 1299116-6, 1N752
Product Details | DIODE SEMICONDUCTOR DEVICE
5961-00-103-7413 A two electrode semiconductor device having an asymmetrical voltage - current characteristic. May or may not include mounting hardware and/or heatsink. Excludes LIGHT EMITTING DIODE and SEMICONDUCTOR DEVICE,PHOTO. For items containing material such as selenium and copper oxide, see RECIFIER, METALLIC.
Part Alternates: 12991166, 1299116-6, 1N752, 5961-00-103-7413, 00-103-7413, 5961001037413, 001037413
Electrical and Electronic Equipment Components | Semiconductor Devices and Associated Hardware
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 12 JUN 1968 | 00-103-7413 | 20589 ( SEMICONDUCTOR DEVICE, DIODE ) |
Cross Reference | NSN 5961-00-103-7413
Part Number | Cage Code | Manufacturer |
---|---|---|
1299116-6 | 01281 | TRW ELECTRONICS AND DEFENSE SECTOR RF DEVICES |
1299116-6 | 03877 | GILBERT ENGINEERING CO INC/INCON SUB OF TRANSITRON ELECTRONIC CORP |
1299116-6 | 04713 | FREESCALE SEMICONDUCTOR, INC. |
1299116-6 | 12954 | MICROSEMI CORP.-SCOTTSDALE DBA MICROSEMI |
1299116-6 | 15238 | ITT SEMICONDUCTORS A DIVISION OF INTERNATIONAL |
1299116-6 | 16352 | C O D I CORP DBA CODI SEMICONDUCTOR INC |
1299116-6 | 19315 | HONEYWELL INTL INC DEFENSE AVIONICS SYSTEMS FORMER BENDIX NAVIGATION AND |
1299116-6 | 55972 | HONEYWELL INTL INC DEFENSE AVIONICS SYSTEMS |
1299116-6 | 81483 | INTERNATIONAL RECTIFIER CORPORATION |
1N752 | 04713 | FREESCALE SEMICONDUCTOR, INC. |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5961-00-103-7413
Related Products | NSN 5961-00-103-7413
Technical Data | NSN 5961-00-103-7413
Characteristic | Specifications |
---|---|
SEMICONDUCTOR MATERIAL | SILICON |
VOLTAGE RATING IN VOLTS PER CHARACTERISTIC | 5.6 MAXIMUM NOMINAL REGULATOR VOLTAGE |
CURRENT RATING PER CHARACTERISTIC | 20.00 MILLIAMPERES MAXIMUM MAXIMUM REVERSE SURGE CURRENT |
POWER RATING PER CHARACTERISTIC | 400.0 MILLIWATTS MAXIMUM TOTAL POWER DISSIPATION |
MAXIMUM OPERATING TEMP PER MEASUREMENT POINT | 175.0 DEG CELSIUS AMBIENT AIR |
INCLOSURE MATERIAL | GLASS |
MOUNTING METHOD | TERMINAL |
TERMINAL LENGTH | 1.000 INCHES MINIMUM |
TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
OVERALL LENGTH | 0.300 INCHES MAXIMUM |
OVERALL DIAMETER | 0.092 INCHES MINIMUM AND 0.130 INCHES MAXIMUM |
FEATURES PROVIDED | HERMETICALLY SEALED CASE |
Restrictions/Controls & Freight Information | NSN 5961-00-103-7413
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 063025 | SEMICONDUCTORS/DEVICES NOI ETC |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 658 | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5961-00-103-7413
Category | Code | Description |
---|---|---|
Cognizance Codes | 9N | Navy-owned stocks of defense electronic material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | S9E | Defense Supply Center Columbus Columbus, OH 43218 |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |