Product Details | DIODE SEMICONDUCTOR DEVICE

5961-00-009-1396 A two electrode semiconductor device having an asymmetrical voltage - current characteristic. May or may not include mounting hardware and/or heatsink. Excludes LIGHT EMITTING DIODE and SEMICONDUCTOR DEVICE,PHOTO. For items containing material such as selenium and copper oxide, see RECIFIER, METALLIC.

Part Alternates: 0N172367, 5961-00-009-1396, 00-009-1396, 5961000091396, 000091396

Electrical and Electronic Equipment Components | Semiconductor Devices and Associated Hardware

Supply Group (FSG) NSN Assign. NIIN
59 28 JUL 1972 00-009-1396

Cross Reference | NSN 5961-00-009-1396

Part Number Cage Code Manufacturer
0N172367 98230 NATIONAL SECURITY AGENCY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5961-00-009-1396

Technical Data | NSN 5961-00-009-1396

Characteristic Specifications
SEMICONDUCTOR MATERIAL SILICON
VOLTAGE RATING IN VOLTS PER CHARACTERISTIC 200.0 MAXIMUM REVERSE VOLTAGE, INSTANTANEOUS
POWER RATING PER CHARACTERISTIC 6.00 WATTS MAXIMUM TOTAL POWER DISSIPATION
MAXIMUM OPERATING TEMP PER MEASUREMENT POINT 200.0 DEG CELSIUS AMBIENT AIR
INCLOSURE MATERIAL METAL
MOUNTING METHOD THREADED STUD
MOUNTING FACILITY QUANTITY 1
THREAD SERIES DESIGNATOR UNF
NOMINAL THREAD SIZE 0.250 INCHES
OVERALL LENGTH 0.450 INCHES NOMINAL
OVERALL WIDTH ACROSS FLATS 0.687 INCHES NOMINAL
FEATURES PROVIDED HERMETICALLY SEALED CASE
TEST DATA DOCUMENT 98230-0N172367 DRAWING
MANUFACTURERS CODE 98230
DESIGN CONTROL REFERENCE 0N172367

Restrictions/Controls & Freight Information | NSN 5961-00-009-1396

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information