NSN 5960-00-636-1053 226T1011, 8867, 00-636-1053
Product Details | ELECTRON TUBE SHIELD
5960-00-636-1053 An item specifically designed to be placed partially or completely around an electron tube for the purpose of shielding against electrical or mechanical interference or physical damage. May include mounting facilities. See also COVER (as modified); HOUSING (as modified) and VISOR (as modified).
Part Alternates: 226T1011, 8867, 5960-00-636-1053, 00-636-1053, 5960006361053, 006361053
Electrical and Electronic Equipment Components | Electron Tubes and Associated Hardware
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 01 JAN 1963 | 00-636-1053 | 10195 ( SHIELD, ELECTRON TUBE ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5960-00-636-1053
Related Products | NSN 5960-00-636-1053
Technical Data | NSN 5960-00-636-1053
Characteristic | Specifications |
---|---|
MATERIAL | COPPER ALLOY |
SURFACE TREATMENT | ANY ACCEPTABLE |
STYLE DESIGNATOR | 12C IRREGULAR |
OVERALL LENGTH | 1.108 INCHES NOMINAL |
OVERALL HEIGHT | 0.313 INCHES NOMINAL |
OVERALL WIDTH | 0.375 INCHES NOMINAL |
ACCOMMODATED ITEM SECURING DEVICE TYPE | FRICTION FASTENER |
MOUNTING FACILITY TYPE AND QUANTITY | 1 SLOT AND 1 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
UNTHREADED MOUNTING HOLE DIAMETER | 0.092 INCHES NOMINAL SINGLE MOUNTING FACILITY |
MOUNTING SLOT WIDTH | 0.078 INCHES NOMINAL SINGLE MOUNTING FACILITY |
MOUNTING SLOT LENGTH | 0.092 INCHES NOMINAL SINGLE MOUNTING FACILITY |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.188 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
EIA ELECTRON TUBE ENVELOPE ACCOMMODATED | T3 3-1 |
MANUFACTURERS CODE | 07421 |
DESIGN CONTROL REFERENCE | 8867 |
Restrictions/Controls & Freight Information | NSN 5960-00-636-1053
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 062800 | RADIO/TV RECEIVING SET CHASSIS ETC |
Less than car load rating | ||
Less than truck load rating | M | 85.0 |
Water commodity Code | 72D | unknown |
Originating Activity Code | XX | |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5960-00-636-1053
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | Q | Electronics Materiel (DLA/GSA Items) |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 00 | DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |