NSN 5960-00-451-0572 578R518H03, 00-451-0572, 004510572
Product Details | ELECTRON TUBE
5960-00-451-0572 An inclosure, including two or more electrodes, in which a flow of electrons may occur through a vacuum or a contained gas. The electronic conduction takes place either by means of electrons emitted from a cathode or by ionization of the contained gas. Includes phototubes (photoemissive type only), Geiger-Mueller tubes, traveling wave tubes, cathode ray tubes and microwave tubes (Klystron, magnetron, or the like). Excludes items whose primary purpose is to produce light energy. Also excludes PHOTOELECTRIC CELL; and SEMICONDUCTOR DEVICE (as modified).
Part Alternates: 578R518H03, 5960-00-451-0572, 00-451-0572, 5960004510572, 004510572
Electrical and Electronic Equipment Components | Electron Tubes and Associated Hardware
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 16 FEB 1972 | 00-451-0572 | 00001 ( ELECTRON TUBE ) |
Cross Reference | NSN 5960-00-451-0572
Part Number | Cage Code | Manufacturer |
---|---|---|
578R518H03 | 97942 | NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NORTHROP GRUMMAN SYSTEMS |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5960-00-451-0572
Related Products | NSN 5960-00-451-0572
Technical Data | NSN 5960-00-451-0572
Characteristic | Specifications |
---|---|
IDENTIFYING NUMBER | 578R518H03 REFERENCE NO. |
ENVELOPE MEDIUM TYPE | VACUUM |
TUBE TYPE | TRAVELING WAVE |
END ITEM IDENTIFICATION | AN/ALQ-119/184 COMMON |
Restrictions/Controls & Freight Information | NSN 5960-00-451-0572
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | P | Munitions List Item. Demilitarization required. Security classified item - Declassification and any additional demilitarization and removal of any sensitive markings or information will be accomplished prior to accountability or physical transfer to a DRMO. This code will not be assigned to AEDA items. |
Controlled Inventory Item Code: | C | CONFIDENTIAL OR MODERATE SENSITIVITY (SRC III) AND LOW SENSITIVITY (SRC IV) - CONFIDENTIAL AA&E. (ITEM WILL BE STORED AND TRANSPORTED IN ACCORDANCE WITH THE PROVISIONS OF DOD 5100.76M OR DOD 5200.1R INFORMATION SECURITY PROGRAM - WHICHEVER IS MORE STRINGENT)./ |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 063470 | ELEC EQUIP:TUBES,ELECTRONIC |
Less than car load rating | M | 85 |
Less than truck load rating | Z | No Rating |
Water commodity Code | 738 | unknown |
Originating Activity Code | TG | Warner-Robins Air Logistics Center Robins AFB, GA 31098-5609 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | V | Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | 3 | Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices). |
Management | NSN 5960-00-451-0572
Category | Code | Description |
---|---|---|
Materiel Management Aggregation Code | EW | TG:AIRBORNE ELECTRONIC WARFARE EQUIPMENT |
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
Source of Supply | FLZ | Warner Robins Air Logistics Center Robins AFB, GA 31098-5609 |
Agency | DF | Department of the Air Force |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | T | AF Recoverable Assembly Management System (AFRAMS) |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | C | CONFIDENTIAL OR MODERATE SENSITIVITY (SRC III) AND LOW SENSITIVITY (SRC IV) - CONFIDENTIAL AA&E. (ITEM WILL BE STORED AND TRANSPORTED IN ACCORDANCE WITH THE PROVISIONS OF DOD 5100.76M OR DOD 5200.1R INFORMATION SECURITY PROGRAM - WHICHEVER IS MORE STRINGENT). |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |