NSN 5960-00-321-0620 L2056, L-2056 , 3731981
Product Details | ELECTRON TUBE
5960-00-321-0620 An inclosure, including two or more electrodes, in which a flow of electrons may occur through a vacuum or a contained gas. The electronic conduction takes place either by means of electrons emitted from a cathode or by ionization of the contained gas. Includes phototubes (photoemissive type only), Geiger-Mueller tubes, traveling wave tubes, cathode ray tubes and microwave tubes (Klystron, magnetron, or the like). Excludes items whose primary purpose is to produce light energy. Also excludes PHOTOELECTRIC CELL; and SEMICONDUCTOR DEVICE (as modified).
Part Alternates: L2056, L-2056 , 3731981, 373198-1, 5960-00-321-0620, 00-321-0620, 5960003210620, 003210620
Electrical and Electronic Equipment Components | Electron Tubes and Associated Hardware
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 24 NOV 1973 | 00-321-0620 | 00001 ( ELECTRON TUBE ) |
Demand History | NSN 5960-00-321-0620
Part Number | Request Date | QTY | Origin |
---|---|---|---|
L-2056 | 2015-03-63 | 13 | |
5960-00-321-0620 | 2015-03-62 | 13 | NECO |
373198-1 | 2014-01-31 | 21 | |
5960-00-321-0620 | 2014-01-30 | 21 | NECO |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5960-00-321-0620
Technical Data | NSN 5960-00-321-0620
Characteristic | Specifications |
---|---|
TUBE TYPE | TRAVELING WAVE |
MANUFACTURERS CODE | 3B150 |
DESIGN CONTROL REFERENCE | 373198-1 |
Restrictions/Controls & Freight Information | NSN 5960-00-321-0620
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | F | Munitions List Item or Commerce Control List Item. Demilitarization required. Demilitarization Instructions to be furnished by the Item/Technical Manager. |
Controlled Inventory Item Code: | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | F | The item is an Aviation Critical Safety Item/Flight Safety Critical Aircraft Part ((ACSI/FSCAP). |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 063476 | TUBES NOI |
Less than car load rating | M | 85 |
Less than truck load rating | W | Rating Variable |
Water commodity Code | 724 | unknown |
Originating Activity Code | HH | Navy ICP Mechanicsburg, PA 17055-0788 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | D | Hazardous material (not required hand to hand receipt) including all regulated items other than special weapons and their components. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | M | Magnetic material |
Management | NSN 5960-00-321-0620
Category | Code | Description |
---|---|---|
Cognizance Codes | 7R | Aeronautical Depot Level Repairable Spares Naval Inventory Control Point, Philadelphia |
Special Material ID | XE | I-CAP II peculiarAIRCRAFT(EA-6B) |
Issue Repair, or Requisition | AR | Repairable item subject to centrally managed rework program at designated sites. Mandatory turn-in of item required except when initial issue or replacement of surveyed item is involved. |
Special Material Content | 2 | Electrostatic Discharge (ESD)/Electromagnetic (EM) Sensitive Item |
Source of Supply | NRP | NAVICP-ERP 700 Robbins Avenue Philadelphia, PA 19111-5098 |
Agency | DN | Department of the Navy |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | E | (1) IRAM Program Intensive Management Reparables (2) Material (expendable ordnance) Requiring Lot and Serial Number Control but which is Reported by Serial Number Only |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |