Product Details | CRYSTAL CONTROLLED OSCILLATOR

5955-01-352-9440 An oscillator whose operating frequency(ies) is controlled by a CRYSTAL UNIT, QUARTZ. For an oscillator controlled by a device other than a crystal, see OSCILLATOR (1), NONCRYSTAL CONTROLLED. See also GENERATOR, SIGNAL; and CALIBRATOR, FREQUENCY. Excludes FREQUENCY SUPPLY, TELEPHONE CARRIER; RESONATOR, TUNING FORK; and OSCILLATOR, PULSE DELAY.20259550038Oscillators and Piezoelectric Crystals59630018Electronic Modules

Part Alternates: M1233000, M123-3000, Q137042110, Q147042110, 4214300010, 5955-01-352-9440, 01-352-9440, 5955013529440, 013529440

Electrical and Electronic Equipment Components | Oscillators and Piezoelectric Crystals

Supply Group (FSG) NSN Assign. NIIN
59 03 FEB 1992 01-352-9440

Drawings & Photos | NSN 5955-01-352-9440


Cross Reference | NSN 5955-01-352-9440

Part Number Cage Code Manufacturer
4214(3000)10 31260 DRS CODEM SYSTEMS INC DIV DRS CODEM SYSTEMS INC. WEST
M123-3000 58792 TECHTROL CYCLONETICS, INC.
Q137042110 66990 ROCKWELL DEL INC SUB OF ROCKWELL INTL CO
Q147042110 66990 ROCKWELL DEL INC SUB OF ROCKWELL INTL CO

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5955-01-352-9440

Technical Data | NSN 5955-01-352-9440

Characteristic Specifications
CIRCUIT CONSTRUCTION TYPE SOLID STATE
FREQUENCY PER CHANNEL 3.0 GIGAHERTZ NOMINAL OPERATING CHANNEL
OPERATING CONTROL METHOD AUTOMATIC
CONTROL TYPE REMOTE
AVERAGE LIFE MEASUREMENT NOT RATED
OPERATING TEMP RANGE 0.0 TO 50.0 DEG CELSIUS
EXTERNAL DC OPERATING VOLTAGE IN VOLTS 26.6 MINIMUM SINGLE VOLTAGE AND 29.4 MAXIMUM SINGLE VOLTAGE
CONNECTION TYPE AND LOCATION GROUND TERMINAL RIGHT SIDE AND RECEPTACLE, COAXIAL RIGHT SIDE AND TERMINAL STUD RIGHT SIDE
CONNECTION CONTACT TYPE AND QUANTITY 1 GROUND TERMINAL EXTERNAL AND 1 RECEPTACLE, COAXIAL EXTERNAL AND 1 TERMINAL STUD EXTERNAL
INCLOSURE TYPE ENCASED
ENVIRONMENTAL PROTECTION MOISTURE PROOF
INSTALLATION DESIGN MECHANICAL
BASIC SHAPE STYLE 1 RECTANGULAR OR SQUARE
OVERALL LENGTH 6.500 INCHES NOMINAL
OVERALL HEIGHT 1.240 INCHES NOMINAL
OVERALL WIDTH 1.400 INCHES NOMINAL
IDENTIFICATION DESIGNATOR Q137042110-66990
III STORAGE TEMP RANGE -62.0 TO 71.0 DEG CELSIUS
III UNPACKAGED UNIT WEIGHT 1.000 POUNDS

Restrictions/Controls & Freight Information | NSN 5955-01-352-9440

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Electro-static Discharge Susceptible:BESD sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 658 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5955-01-352-9440

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each