Product Details | CRYSTAL CONTROLLED OSCILLATOR

5955-01-189-6830 An oscillator whose operating frequency(ies) is controlled by a CRYSTAL UNIT, QUARTZ. For an oscillator controlled by a device other than a crystal, see OSCILLATOR (1), NONCRYSTAL CONTROLLED. See also GENERATOR, SIGNAL; and CALIBRATOR, FREQUENCY. Excludes FREQUENCY SUPPLY, TELEPHONE CARRIER; RESONATOR, TUNING FORK; and OSCILLATOR, PULSE DELAY.20259550038Oscillators and Piezoelectric Crystals59630018Electronic Modules

Part Alternates: MC 282X7-002W, MC282X7002W, SMA8845831, SM-A-884583-1, TK 557-1, TK5571, 7472WOA1, 7472-WOA-1, 5955-01-189-6830, 01-189-6830, 5955011896830, 011896830

Electrical and Electronic Equipment Components | Oscillators and Piezoelectric Crystals

Supply Group (FSG) NSN Assign. NIIN
59 18 SEP 1984 01-189-6830

Drawings & Photos | NSN 5955-01-189-6830


Cross Reference | NSN 5955-01-189-6830

Part Number Cage Code Manufacturer
7472-WOA-1 17304 DAMON CORP ELECTRONICS DIV
MC 282X7-002W 00136 VECTRON INTERNATIONAL, INC.
SM-A-884583-1 80063 US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS
TK 557-1 11869 ST OLEKTRON CORP

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5955-01-189-6830

Technical Data | NSN 5955-01-189-6830

Characteristic Specifications
CIRCUIT CONSTRUCTION TYPE SOLID STATE
FREQUENCY PER CHANNEL 9.83 MEGAHERTZ NOMINAL OUTPUT CHANNEL
AVERAGE POWER RATING PER CHANNEL 350.0 MILLIWATTS INPUT
OPERATING CONTROL METHOD MANUAL
CONTROL TYPE LOCAL
AVERAGE LIFE MEASUREMENT NOT RATED
OPERATING TEMP RANGE -32.0 TO 85.0 DEG CELSIUS
EXTERNAL DC OPERATING VOLTAGE IN VOLTS 5.0 NOMINAL 1ST VOLTAGE 12.0 NOMINAL 2ND VOLTAGE
CONNECTION TYPE AND LOCATION PIN BOTTOM
CONNECTION CONTACT TYPE AND QUANTITY 7 PIN EXTERNAL
INCLOSURE TYPE ENCASED
INSTALLATION DESIGN MODULE
BASIC SHAPE STYLE 1 RECTANGULAR OR SQUARE
OVERALL LENGTH 2.500 INCHES MAXIMUM
OVERALL HEIGHT 0.655 INCHES MAXIMUM
OVERALL WIDTH 2.010 INCHES MAXIMUM
IDENTIFICATION DESIGNATOR SM-A-884583-1-80063
III STORAGE TEMP RANGE -57.0 TO 85.0 DEG CELSIUS
III END ITEM IDENTIFICATION 5820-01-145-2459,MULTIPLEXER

Restrictions/Controls & Freight Information | NSN 5955-01-189-6830

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code TH Defense Supply Center Columbus
Columbus, OH 43215
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5955-01-189-6830

Category Code Description
Materiel Category and Inventory ManagerQ Electronics Materiel (DLA/GSA Items)
Appropriation and Budget Activity2 Stock Fund Secondary Items
Management Inventory Segment2 NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable.
Specific Group/Generic Code0 Medical Materiel
Weapons Systems/End Item or Homogeneous Group00DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item
Accounting Requirements CodeX Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDADepartment of the Army
Service OrganizationAU.S. Army
ReparabilityZThis is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item.
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each