Product Details | CRYSTAL CONTROLLED OSCILLATOR

5955-01-150-0312 An oscillator whose operating frequency(ies) is controlled by a CRYSTAL UNIT, QUARTZ. For an oscillator controlled by a device other than a crystal, see OSCILLATOR (1), NONCRYSTAL CONTROLLED. See also GENERATOR, SIGNAL; and CALIBRATOR, FREQUENCY. Excludes FREQUENCY SUPPLY, TELEPHONE CARRIER; RESONATOR, TUNING FORK; and OSCILLATOR, PULSE DELAY.20259550038Oscillators and Piezoelectric Crystals59630018Electronic Modules

Part Alternates: 1415010003, 141501-0003, 238A-1S-0 AT 6MHZ, 238A1S0AT6MHZ, 238AIS0AT6MHZ, 238A-IS-0AT6MHZ, 5955-01-150-0312, 01-150-0312, 5955011500312, 011500312

Electrical and Electronic Equipment Components | Oscillators and Piezoelectric Crystals

Supply Group (FSG) NSN Assign. NIIN
59 29 MAR 1983 01-150-0312

Drawings & Photos | NSN 5955-01-150-0312


Cross Reference | NSN 5955-01-150-0312

Part Number Cage Code Manufacturer
141501-0003 19397 BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.
238A-1S-0 AT 6MHZ 00136 VECTRON INTERNATIONAL, INC.
238A-1S-0 AT 6MHZ 27802 VECTRON INTERNATIONAL DIV. OF DOVER ELECTRONICS INC
238A-IS-0AT6MHZ 27802 VECTRON INTERNATIONAL DIV. OF DOVER ELECTRONICS INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5955-01-150-0312

Technical Data | NSN 5955-01-150-0312

Characteristic Specifications
CIRCUIT CONSTRUCTION TYPE SOLID STATE
FREQUENCY PER CHANNEL 6.0 MEGAHERTZ NOMINAL OUTPUT CHANNEL
ATTENUATION IN DECIBELS NOT RATED
AVERAGE POWER RATING PER CHANNEL NOT RATED
SIGNAL VOLTAGE RATING PER CHANNEL 0.400 VOLTS MINIMUM OUTPUT AND 2.400 VOLTS MAXIMUM OUTPUT
OVERALL GAIN NOT RATED
IMPEDANCE RATING PER CHANNEL NOT RATED
MAXIMUM CONTINUOUS OPERATING TIME IN HOURS NOT RATED
AVERAGE LIFE MEASUREMENT NOT RATED
MAXIMUM OPERATING ALTITUDE RATING NOT RATED
OPERATING TEMP RANGE -55.0 TO 85.0 DEG CELSIUS
VIBRATION RESISTANCE RANGE IN HERTZ 1.0 TO 10.0
SHOCK RESISTANCE RATING IN GRAVITATIONAL UNITS NOT RATED
EXTERNAL DC OPERATING VOLTAGE IN VOLTS 5.0 NOMINAL SINGLE VOLTAGE
CONNECTION TYPE AND LOCATION PRINTED CIRCUIT BOTTOM
CONNECTION CONTACT TYPE AND QUANTITY 14 PRINTED CIRCUIT EXTERNAL
INCLOSURE TYPE HERMETICALLY SEALED
ENVIRONMENTAL PROTECTION SHOCK RESISTANT AND VIBRATION
INSTALLATION DESIGN MODULE
BASIC SHAPE STYLE 1 RECTANGULAR OR SQUARE
OVERALL LENGTH 0.800 INCHES NOMINAL
OVERALL HEIGHT 0.350 INCHES NOMINAL
OVERALL WIDTH 0.500 INCHES NOMINAL
IDENTIFICATION DESIGNATOR 238A-1S-0 AT 6MHZ-27802
III END ITEM IDENTIFICATION JETDS NO. AN/UGC-129(V),TELETYPEWRITER SET

Restrictions/Controls & Freight Information | NSN 5955-01-150-0312

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5955-01-150-0312

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each