Product Details | NONCRYSTAL CONTROLLED OSCILLATOR

5955-01-010-7859 An oscillator whose operating frequency(ies) is controlled by an electronic device other than a CRYSTAL UNIT, QUARTZ. For an oscillator controlled by a crystal, see OSCILLATOR (1), CRYSTAL CONTROLLED. See also GENERATOR, SIGNAL; and CALIBRATOR, FREQUENCY. Excludes FREQUENCY SUPPLY, TELEPHONE CARRIER; RESONATOR, TUNING FORK; and OSCILLATOR, PULSE DELAY.20259550038Oscillators and Piezoelectric Crystals59630018Electronic Modules

Part Alternates: 03342801AND 033787, 03342801AND033787, 25262, 5955-01-010-7859, 01-010-7859, 5955010107859, 010107859

Electrical and Electronic Equipment Components | Oscillators and Piezoelectric Crystals

Supply Group (FSG) NSN Assign. NIIN
59 06 OCT 1975 01-010-7859

Drawings & Photos | NSN 5955-01-010-7859


Cross Reference | NSN 5955-01-010-7859

Part Number Cage Code Manufacturer
03342801AND 033787 54626 SYSTRON-DONNER CORP NATIONAL SERVICE DIV
25262 06811 BEI SENSORS & SYSTEMS COMPANY, INC. DBA SYSTRON DONNER INERTIAL

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5955-01-010-7859

Technical Data | NSN 5955-01-010-7859

Characteristic Specifications
CIRCUIT CONSTRUCTION TYPE ANY ACCEPTABLE
FREQUENCY PER CHANNEL 3.0 MEGAHERTZ NOMINAL OUTPUT CHANNEL
ATTENUATION IN DECIBELS NOT RATED
AVERAGE POWER RATING PER CHANNEL 12.0 WATTS INPUT
SIGNAL VOLTAGE RATING PER CHANNEL 28.000 VOLTS NOMINAL INPUT
OVERALL GAIN NOT RATED
IMPEDANCE RATING PER CHANNEL NOT RATED
OPERATING CONTROL METHOD AUTOMATIC
MAXIMUM CONTINUOUS OPERATING TIME IN HOURS NOT RATED
AVERAGE LIFE MEASUREMENT NOT RATED
MAXIMUM OPERATING ALTITUDE RATING NOT RATED
OPERATING TEMP RANGE -15.0 TO 60.0 DEG CELSIUS
VIBRATION RESISTANCE RANGE IN HERTZ NOT RATED
SHOCK RESISTANCE RATING IN GRAVITATIONAL UNITS NOT RATED
EXTERNAL DC OPERATING VOLTAGE IN VOLTS 28.0 NOMINAL SINGLE VOLTAGE
CONNECTION TYPE AND LOCATION QUICK DISCONNECT AND TURRET ON FRONT
CONNECTION CONTACT TYPE AND QUANTITY QUICK DISCONNECT EXTERNAL 2 AND TURRET EXTERNAL 3
INCLOSURE TYPE ENCASED
INSTALLATION DESIGN MECHANICAL
BASIC SHAPE STYLE 1 RECTANGULAR OR SQUARE
OVERALL LENGTH 4.966 INCHES NOMINAL
OVERALL HEIGHT 1.600 INCHES MAXIMUM
OVERALL WIDTH 2.880 INCHES MAXIMUM
IDENTIFICATION DESIGNATOR 25262-06811
III FSC APPLICATION DATA TEST SETS,ELECTRONIC SYSTEMS,EXCEPT SPECIALLY DESIGNED

Restrictions/Controls & Freight Information | NSN 5955-01-010-7859

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061700 ELEC APPLIANCES/INSTRUMENTS NOI
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5955-01-010-7859

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each