NSN 5950-01-611-4652 PE68280NL, PE-68280NL , 01-611-4652
Product Details | CURRENT TRANSFORMER
5950-01-611-4652 An item consisting of one or more windings, designed to be placed near or connected in series with an alternating current power line to measure the current passing through the line by means of a meter; or to control the current passing through the line by means of a control device. Excludes TRANSFORMER, POWER, CURRENT REGULATING.
Part Alternates: PE68280NL, PE-68280NL , 5950-01-611-4652, 01-611-4652, 5950016114652, 016114652
Electrical and Electronic Equipment Components | Coils and Transformers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 2012258 | 01-611-4652 | 00738 ( TRANSFORMER, CURRENT ) |
Cross Reference | NSN 5950-01-611-4652
Part Number | Cage Code | Manufacturer |
---|---|---|
PE-68280NL | 90095 | PULSE ELECTRONICS CORPORATION DBA PULSE COMPONENTS DIVISION |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5950-01-611-4652
Related Products | NSN 5950-01-611-4652
Technical Data | NSN 5950-01-611-4652
Characteristic | Specifications |
---|---|
FREQUENCY RATING | 50.0 KILOHERTZ MINIMUM AND |
MOUNTING METHOD | TERMINAL SINGLE GROUP |
INCLOSURE TYPE | FULLY INCLOSED |
OVERALL LENGTH | 0.495 INCHES NOMINAL |
OVERALL HEIGHT | 0.280 INCHES MAXIMUM |
OVERALL WIDTH | 0.495 INCHES MAXIMUM |
RELIABILITY INDICATOR | NOT ESTABLISHED |
SPECIAL FEATURES | 1:1:100TURN RATIO; 15A MINIMUM CURRENT; 14.8MH SECONDARY INDUCTANCE; 1.15 MILLOHM MAXIMUM PRIMARY DCR; 930 MILIOHM MAXIMUM SECONDARY DCR |
Restrictions/Controls & Freight Information | NSN 5950-01-611-4652
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |