Product Details | POWER TRANSFORMER

5950-01-211-5144 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: T00689, T0689, 5950-01-211-5144, 01-211-5144, 5950012115144, 012115144

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 27 JUN 1985 01-211-5144

Demand History | NSN 5950-01-211-5144

Part Number Request Date QTY Origin
T00689 2021-11-325 1 DIBBS
5950-01-211-5144 2008-02-34 1 DIBBS

Cross Reference | NSN 5950-01-211-5144

Part Number Cage Code Manufacturer
T00689 12867 GSE HOLDINGS INC. DBA ITW MILITARY GSE
T0689 12867 GSE HOLDINGS INC. DBA ITW MILITARY GSE

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-211-5144

Technical Data | NSN 5950-01-211-5144

Characteristic Specifications
MOUNTING HOLE DIAMETER 0.344 INCHES NOMINAL SINGLE GROUP
WINDING OPERATING VOLTAGE 23.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE 254.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY
WINDING OPERATING CURRENT 2.6 AMPERES AC MAXIMUM SINGLE COMPONENT ALL PRIMARY
MOUNTING METHOD UNTHREADED HOLE SINGLE GROUP
BODY HEIGHT 8.100 INCHES NOMINAL
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 6.312 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
RELIABILITY INDICATOR NOT ESTABLISHED
WINDING OPERATING CURRENT 41.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
TERMINAL TYPE AND QUANTITY 10 TERMINAL BLOCK W/SCREWS
WINDING OPERATING VOLTAGE 160.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT 41.0 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT 41.0 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING FUNCTION AND QUANTITY 3 PRIMARY AND 6 SECONDARY SINGLE COMPONENT
BODY WIDTH 4.625 INCHES NOMINAL
WINDING OPERATING VOLTAGE 160.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE 160.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
SPECIAL FEATURES 3 PRIMARY WINDINGS; 6 SECONDARY WINDINGS
FREQUENCY RATING 60.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING OPERATING CURRENT 500.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 10.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO THREE PHASE SINGLE COMPONENT
TRANSFORMER WINDING CONNECTION TYPE WYE-DELTA
BODY LENGTH 10.000 INCHES NOMINAL
INCLOSURE TYPE FULLY INCLOSED

Restrictions/Controls & Freight Information | NSN 5950-01-211-5144

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-01-211-5144

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each