Product Details | POWER TRANSFORMER

5950-01-126-7049 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: W50HG2M, 5950-01-126-7049, 01-126-7049, 5950011267049, 011267049

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 15 FEB 1982 01-126-7049

Cross Reference | NSN 5950-01-126-7049

Part Number Cage Code Manufacturer
W50HG2M 13850 TECHNIPOWER LLC DBA UNIPOWER

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-126-7049

Technical Data | NSN 5950-01-126-7049

Characteristic Specifications
MAXIMUM TRANSFORMER POWER RATING 12.9 VOLT-AMPERE SINGLE COMPONENT
OVERALL LENGTH 14.000 INCHES NOMINAL
OVERALL HEIGHT 17.000 INCHES NOMINAL
OVERALL WIDTH 13.000 INCHES NOMINAL
MANUFACTURERS CODE 13850
DESIGN CONTROL REFERENCE W50HG2M

Restrictions/Controls & Freight Information | NSN 5950-01-126-7049

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code TA Sacramento Air Logistics Center
McClellan AFB, CA 95652-5609
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable