Product Details | PULSE TRANSFORMER

5950-01-126-2891 A transformer designed to transfer pulses of nonsinusoidal wave forms between circuits without basically changing the wave forms.

Part Alternates: ES16871, ES1687-1 , G87302, 8451022, 845102-2, 176026, 5950-01-126-2891, 01-126-2891, 5950011262891, 011262891

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 09 FEB 1982 01-126-2891

Cross Reference | NSN 5950-01-126-2891

Part Number Cage Code Manufacturer
176026 64196 VOLTAMPERE CORP
845102-2 00779 TYCO ELECTRONICS CORPORATION
ES1687-1 20418 DRS SUSTAINMENT SYSTEMS, INC. Use CAGE Code 98255 for cataloging
ES1687-1 98255 DRS SUSTAINMENT SYSTEMS, INC.
G87302 1F702 GAUSS CONTROL INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-126-2891

Technical Data | NSN 5950-01-126-2891

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 6 SOLDER STUD AND 2 STANDOFF, THREADED STUD AND 1 TAB, SOLDER LUG
WINDING OPERATING CURRENT 2.4 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY 1.6 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
(NON-CORE DATA) PEAK VOLTAGE RATING 4.2 KILOVOLTS SINGLE COMPONENT ALL PRIMARY 18.0 KILOVOLTS SINGLE COMPONENT ALL SECONDARY
DC RESISTANCE RATING IN OHMS 1100.000 SINGLE COMPONENT ALL PRIMARY
IMPEDANCE RATING IN OHMS 48.0 NOMINAL SINGLE COMPONENT ALL PRIMARY
FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
(NON-CORE DATA) PULSE DURATION IN MICROSECONDS 0.430 SINGLE COMPONENT
PULSE REPETITION RATE 2.0 KILOHERTZ SINGLE COMPONENT
WINDING SHIELDING METHOD INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 2 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
MOUNTING METHOD BRACKET AND UNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 6 SINGLE GROUP
MOUNTING HOLE DIAMETER 0.196 INCHES NOMINAL SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 4.440 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.810 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE HERMETICALLY SEALED
BODY LENGTH 3.325 INCHES NOMINAL
BODY HEIGHT 4.120 INCHES NOMINAL
BODY WIDTH 3.120 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
(NON-CORE DATA) CUBIC MEASURE 42.7 CUBIC INCHES

Restrictions/Controls & Freight Information | NSN 5950-01-126-2891

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-01-126-2891

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each