Product Details | POWER TRANSFORMER

5950-01-120-7775 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 1260405, 126040-5, 5950-01-120-7775, 01-120-7775, 5950011207775, 011207775

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 22 OCT 1981 01-120-7775

Cross Reference | NSN 5950-01-120-7775

Part Number Cage Code Manufacturer
126040-5 10138 ASTRONAUTICS CORPORATION OF AMERICA

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-120-7775

Technical Data | NSN 5950-01-120-7775

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 4 WIRE LEAD
WINDING OPERATING CURRENT 2.3 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY 2.3 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY
FREQUENCY RATING 800.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT
MOUNTING METHOD THREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
THREAD SERIES DESIGNATOR UNC SINGLE GROUP
NOMINAL THREAD SIZE 0.112 INCHES SINGLE GROUP
THREAD QUANTITY PER INCH 40 SINGLE GROUP
(NON-CORE DATA) THREAD CLASS 2B SINGLE GROUP
(NON-CORE DATA) THREAD LENGTH 5.500 INCHES MINIMUM SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 0.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE OPEN
OVERALL LENGTH 1.900 INCHES MAXIMUM
OVERALL HEIGHT 1.060 INCHES MAXIMUM
OVERALL WIDTH 1.720 INCHES NOMINAL
III MAXIMUM OPERATING TEMP 115.0 DEG CELSIUS

Restrictions/Controls & Freight Information | NSN 5950-01-120-7775

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information