NSN 5950-01-120-5098 6C1260, 6C12-60, 01-120-5098
Product Details | POWER TRANSFORMER
5950-01-120-5098 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station
Part Alternates: 6C1260, 6C12-60, 5950-01-120-5098, 01-120-5098, 5950011205098, 011205098
Electrical and Electronic Equipment Components | Coils and Transformers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 20 OCT 1981 | 01-120-5098 | 32496 ( TRANSFORMER, POWER ) |
Cross Reference | NSN 5950-01-120-5098
Part Number | Cage Code | Manufacturer |
---|---|---|
6C12-60 | 15755 | SURE POWER, INC. DBA MARTEK POWER |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5950-01-120-5098
Technical Data | NSN 5950-01-120-5098
Characteristic | Specifications |
---|---|
TERMINAL TYPE AND QUANTITY | 6 WIRE HOOK |
WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY 12.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
WINDING OPERATING CURRENT | 2.4 AMPERES AC NOMINAL SINGLE COMPONENT ALL SECONDARY |
FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 65.0 HERTZ MAXIMUM SINGLE COMPONENT |
WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
MOUNTING METHOD | THREADED STUD SINGLE GROUP |
MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
(NON-CORE DATA) THREAD CLASS | 2A SINGLE GROUP |
(NON-CORE DATA) THREAD DIRECTION | RIGHT-HAND SINGLE GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.281 INCHES MINIMUM AND 2.297 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.843 INCHES MINIMUM AND 1.859 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
INCLOSURE TYPE | FULLY INCLOSED |
OVERALL LENGTH | 2.937 INCHES MINIMUM AND 3.062 INCHES MAXIMUM |
OVERALL HEIGHT | 4.375 INCHES MINIMUM AND 4.687 INCHES MAXIMUM |
OVERALL WIDTH | 2.500 INCHES MINIMUM AND 2.625 INCHES MAXIMUM |
RELIABILITY INDICATOR | NOT ESTABLISHED |
(NON-CORE DATA) DUMMY TERMINAL QUANTITY | 1 |
III MAXIMUM OPERATING TEMP | 90.0 DEG CELSIUS |
(NON-CORE DATA) UNPACKAGED UNIT WEIGHT | 4.700 POUNDS |
(NON-CORE DATA) CUBIC MEASURE | 37.2 CUBIC INCHES |
Restrictions/Controls & Freight Information | NSN 5950-01-120-5098
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 595 | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5950-01-120-5098
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |