NSN 5950-01-118-3897 L504000459, TF5S03ZZ, TF5SXD1JA
Product Details | POWER TRANSFORMER
5950-01-118-3897 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station
Part Alternates: L504000459, TF5S03ZZ, TF5SXD1JA, TRR5667, TRR-5667, 11011, 61556007, 61556-007, 5950-01-118-3897, 01-118-3897, 5950011183897, 011183897
Electrical and Electronic Equipment Components | Coils and Transformers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 03 SEP 1981 | 01-118-3897 | 32496 ( TRANSFORMER, POWER ) |
Demand History | NSN 5950-01-118-3897
Part Number | Request Date | QTY | Origin |
---|---|---|---|
5950-01-118-3897 | 2018-06-176 | 15 | DIBBS |
5950-01-118-3897 | 2018-06-165 | 15 | DIBBS |
5950-01-118-3897 | 2012-06-180 | 1 | United States |
5950-01-118-3897 | 2010-11-323 | 9 | DIBBS |
5950-01-118-3897 | 2010-07-183 | 5 | DIBBS |
5950-01-118-3897 | 2009-11-307 | 5 | DIBBS |
5950-01-118-3897 | 2008-12-349 | 5 | EG |
Cross Reference | NSN 5950-01-118-3897
Part Number | Cage Code | Manufacturer |
---|---|---|
11011 | 55196 | SORA POWER INC. DBA SIGMA DIVISION |
61556-007 | 12763 | DYNALEC CORPORATION |
L504000459 | 36090 | LOCKHEED MARTIN LIBRASCOPE CORP |
TF5S03ZZ | 88691 | ELECTRIC TRANSFORMER CORP |
TF5SXD1JA | 73386 | FREED TRANSFORMER COMPANY |
TRR-5667 | 51170 | I-T-E IMPERIAL CORP SUBSIDIARY OF GOULD INC |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5950-01-118-3897
Technical Data | NSN 5950-01-118-3897
Characteristic | Specifications |
---|---|
TERMINAL TYPE AND QUANTITY | 9 TAB, SOLDER LUG |
WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
MOUNTING HOLE DIAMETER | 0.180 INCHES NOMINAL SINGLE GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
INCLOSURE TYPE | OPEN |
BODY LENGTH | 4.380 INCHES MAXIMUM |
BODY HEIGHT | 1.620 INCHES MAXIMUM |
BODY WIDTH | 2.430 INCHES MAXIMUM |
OVERALL LENGTH | 4.380 INCHES MAXIMUM |
OVERALL HEIGHT | 1.620 INCHES MAXIMUM |
OVERALL WIDTH | 3.850 INCHES MAXIMUM |
RELIABILITY INDICATOR | NOT ESTABLISHED |
SPECIAL FEATURES | VOLT AMPERE RATING 175 VA MIN |
III TRANSFORMER WINDING CONNECTION TYPE | DELTA-DELTA |
Restrictions/Controls & Freight Information | NSN 5950-01-118-3897
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 595 | unknown |
Originating Activity Code | ZA | Australia ZB ZC |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5950-01-118-3897
Category | Code | Description |
---|---|---|
Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
Combat Essentiality Code | 0 | Non-combat Essential End Item. End items that do not fit the definition of Code 1 items. |
Materiel Management Code | B | All CommoditiesDefense Logistics Agency, (DLA,) |
Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DM | U.S. Marine Corps |
Service Organization | M | U.S. Marine Corps |
Reparability | Z | Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code. |
Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |