Product Details | POWER TRANSFORMER

5950-01-118-0018 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 35-0296-101, 5850, 5950-01-118-0018, 01-118-0018, 5950011180018, 350296101, 011180018

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 25 AUG 1981 01-118-0018

Drawings & Photos | NSN 5950-01-118-0018


Demand History | NSN 5950-01-118-0018

Part Number Request Date QTY Origin
5950-01-118-0018 2019-11-331 1 Taiwan
35-0296-101 2019-11-308 2 DIBBS
5850 2019-11-308 2 DIBBS
35-0296-101 2019-10-296 2 DIBBS
5850 2019-10-296 2 DIBBS
5950-01-118-0018 2017-10-303 1 DIBBS
5950-01-118-0018 2015-05-141 1 DIBBS
5950-01-118-0018 2015-05-130 1 DIBBS
5950-01-118-0018 2014-09-251 1 Taiwan
5950-01-118-0018 2011-05-137 1 Taiwan

Cross Reference | NSN 5950-01-118-0018

Part Number Cage Code Manufacturer
35-0296-101 26581 HAMILTON SUNDSTRAND CORPORATION DBA APPLIED SCIENCE OPERATION
5850 11537 SARTRON INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-118-0018

Technical Data | NSN 5950-01-118-0018

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 9 SOLDER STUD AND 3 THREADED STUD
(NON-CORE DATA) WINDING TAP LOCATION CENTER TAP SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE 22.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 18.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY 18.50 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY 18.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT 4.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY 500.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY 500.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY 12.0 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
FREQUENCY RATING 55.0 HERTZ MINIMUM AND 65.0 HERTZ MAXIMUM SINGLE COMPONENT
WINDING SHIELDING METHOD INTERNALLY SHIELDED AND BROUGHT OUT TO PRIMARY TERMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD THREADED STUD SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
THREAD SERIES DESIGNATOR UNC SINGLE GROUP
NOMINAL THREAD SIZE 0.250 INCHES SINGLE GROUP
THREAD QUANTITY PER INCH 20 SINGLE GROUP
(NON-CORE DATA) THREAD CLASS 2A SINGLE GROUP
(NON-CORE DATA) THREAD DIRECTION RIGHT-HAND SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE HERMETICALLY SEALED
BODY LENGTH 4.720 INCHES MAXIMUM
BODY HEIGHT 4.938 INCHES MAXIMUM
BODY WIDTH 4.030 INCHES MAXIMUM
OVERALL HEIGHT 5.626 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
III MAXIMUM OPERATING TEMP 100.0 DEG CELSIUS

Restrictions/Controls & Freight Information | NSN 5950-01-118-0018

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-01-118-0018

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each