NSN 5950-01-114-8995 30043F00M00R01, 30-043F00M00R01, 01-114-8995
Product Details | POWER TRANSFORMER
5950-01-114-8995 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station
Part Alternates: 30043F00M00R01, 30-043F00M00R01, 5950-01-114-8995, 01-114-8995, 5950011148995, 011148995
Electrical and Electronic Equipment Components | Coils and Transformers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 24 JUN 1981 | 01-114-8995 | 32496 ( TRANSFORMER, POWER ) |
Cross Reference | NSN 5950-01-114-8995
Part Number | Cage Code | Manufacturer |
---|---|---|
30-043F00M00R01 | 30331 | CONCURRENT COMPUTER CORPORATION |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5950-01-114-8995
Technical Data | NSN 5950-01-114-8995
Characteristic | Specifications |
---|---|
WINDING OPERATING VOLTAGE | 12.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
OVERALL WIDTH | 1.750 INCHES NOMINAL |
WINDING POWER RATING | 4.8 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.810 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
OVERALL LENGTH | 3.200 INCHES MAXIMUM |
WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
WINDING OPERATING VOLTAGE | 16.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
RELIABILITY INDICATOR | NOT ESTABLISHED |
MOUNTING HOLE DIAMETER | 0.188 INCHES NOMINAL SINGLE GROUP |
OVERALL HEIGHT | 2.620 INCHES NOMINAL |
WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
WINDING OPERATING CURRENT | 200.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
WINDING OPERATING VOLTAGE | 24.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
WINDING POWER RATING | 12.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
TERMINAL TYPE AND QUANTITY | 10 TAB, SOLDER LUG |
FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
WINDING OPERATING CURRENT | 750.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
WINDING POWER RATING | 12.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
WINDING OPERATING CURRENT | 750.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
INCLOSURE TYPE | FULLY INCLOSED |
Restrictions/Controls & Freight Information | NSN 5950-01-114-8995
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 595 | unknown |
Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5950-01-114-8995
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |