Product Details | POWER TRANSFORMER

5950-01-082-5626 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 1617934, 5950-01-082-5626, 01-082-5626, 5950010825626, 010825626

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 06 SEP 1979 01-082-5626

Demand History | NSN 5950-01-082-5626

Part Number Request Date QTY Origin
5950-01-082-5626 2006-05-128 4 United States

Cross Reference | NSN 5950-01-082-5626

Part Number Cage Code Manufacturer
1617934 05869 RAYTHEON COMPANY DBA RAYTHEON

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-082-5626

Technical Data | NSN 5950-01-082-5626

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 9 WIRE LEAD
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING METHOD UNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 2 SINGLE GROUP
DISTANCE BETWEEN MOUNTING FACILITY CENTERS 1.320 INCHES MINIMUM AND 1.380 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE OPEN
BODY LENGTH 1.570 INCHES MINIMUM AND 1.630 INCHES MAXIMUM
BODY HEIGHT 1.320 INCHES MINIMUM AND 1.380 INCHES MAXIMUM
BODY WIDTH 1.370 INCHES MINIMUM AND 1.430 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
SPECIAL FEATURES ONE INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL; TWO INTERNAL SHIELDS BROUGHT OUT TO TERMINALS
III END ITEM IDENTIFICATION 5840-01-073-5675

Restrictions/Controls & Freight Information | NSN 5950-01-082-5626

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating P 77.5
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code CL U.S. Army Communications-Electronics
Fort Monmouth, NJ 07703-5006
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable