Product Details | POWER TRANSFORMER

5950-01-079-4485 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 768812 , 8375391, 837539-1, 5950-01-079-4485, 01-079-4485, 5950010794485, 010794485

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 06 JUL 1979 01-079-4485

Cross Reference | NSN 5950-01-079-4485

Part Number Cage Code Manufacturer
768812 A0810 SELEX ES SPA
837539-1 96214 RAYTHEON COMPANY DBA RAYTHEON
837539-1 A0072 FIAR FABBRICA ITALIANA APPARECCHIATURE RADIOELETTRICHE SPA

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-01-079-4485

Technical Data | NSN 5950-01-079-4485

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 18 TAB, SOLDER LUG
(NON-CORE DATA) WINDING TAP LOCATION CENTER TAP SINGLE COMPONENT ALL SECONDARY
WINDING OPERATING VOLTAGE 76.40 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 2480.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY 40.50 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY 9.15 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY 97.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY
WINDING OPERATING CURRENT 24.5 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY 2.5 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY 5.7 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY 533.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 3 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO THREE PHASE SINGLE COMPONENT
MOUNTING METHOD THREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
THREAD SERIES DESIGNATOR UNC SINGLE GROUP
NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP
THREAD QUANTITY PER INCH 32 SINGLE GROUP
(NON-CORE DATA) THREAD CLASS 2B SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.220 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE FULLY INCLOSED
OVERALL LENGTH 3.450 INCHES MAXIMUM
OVERALL HEIGHT 2.350 INCHES MAXIMUM
OVERALL WIDTH 2.800 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
III TRANSFORMER WINDING CONNECTION TYPE WYE-DELTA AND WYE-WYE
III MAXIMUM OPERATING TEMP 155.0 DEG CELSIUS
(NON-CORE DATA) SUPPLEMENTARY FEATURES CM55.0/P125.0
MANUFACTURERS CODE 96214
DESIGN CONTROL REFERENCE 837539-1

Restrictions/Controls & Freight Information | NSN 5950-01-079-4485

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information